background image

 

Version 1,29

th

 January 2021, Page 

1

 of 

4

 

Ezy-Drink

®

 SS Lead Safe Wall Mounted Lever Action 

Bottle Filler  

 

PRODUCT CODES: 

 

 

34990X 

 

SPECIFICATIONS

 

 

Bottle filler taps are designed to operate at full mains pressure. 

 

Lead Safe stainless steel construction 

 

Adjustable built-in flow restrictor.

 

IMPORTANT: All Ezy-Drink

®

 lever bottle filler taps are tested in accordance with AS/NZS 3718 and leave 

our premises in good working order. 

 

 

TECHNICAL DATA

 

Inlet

 

½” BSP - Female 

Outlet 

Water diffuser 

Headwork 

Lever action 

Working Pressure Range (kPa)  

Min 

50 

Max 

500 

Working Temperature Range (°C) 

Min 

Max 

60 

Nominal Flow Rate (LPM) 

1.7 

Finish 

Stainless Steel 

NOTE: Galvin Engineering continually strive to improve their products.  Specifications may change without 
notice.

 

 

TOOLS REQUIRED

 

 

Power drill

 

 

Spanner or adjustable crescent  

 

  Screw driver

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ezy-Drink SS

Page 1: ...nk lever bottle filler taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECHNICAL DATA Inlet BSP Female Outlet Water diffuser Headwork Lever action Working Pressure Range kPa Min 50 Max 500 Working Temperature Range C Min 5 Max 60 Nominal Flow Rate LPM 1 7 Finish Stainless Steel NOTE Galvin Engineering continually strive to improve their products Specific...

Page 2: ... requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provisions shall void the product warranty and may affect the performance of the product When applying thread tape or sealant to the inlet ensure the opening is not blocked Failure to do so may cause the regulating screw to be blocked which will af...

Page 3: ...NG PROBLEM CAUSE RECTIFICATION Inconsistent flow Blocked top assembly or regulating screw Remove top assembly and or regulating screw and clean Water is not flowing from tap Water is turned off Turn on water Blocked regulating screw Remove regulating screw and clean Continuous flow Top assembly loose or internally obstructed or damaged Remove top assembly clean with water and re grease spindle if ...

Page 4: ...manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s warranty are complied with The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and Galvin Engineering Pty Ltd sh...