Product Installation Guidelines 

Version 2.1, 2 December 2021, Page 

2

 of 6 

 

 
 

DIMENSIONS

 

 
 

If the mounting hole does not already exist, 
mark out and drill the hole in the sink, as 
shown in the rough-in dimensions. 

 

Note: Before installation, all lines must be flushed. We 
recommend that a line strainer be installed prior to the 
CliniLever® Sink Mixer to eliminate any foreign 
material. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION

 

INSTALLATION  COMPLIANCE:  Galvin  Engineering  products  must  be  installed  in  accordance  with  these 
installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. 
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards. 
Failing to comply with these provisions shall void the product warranty and may affect the performance of the 
product. 

  
 

 
 

 

 
 
 
 
 
 
 
 
 
 

 

 

1.  Fit Mounting Hardware and Hoses 

 

Screw in and tighten flexi-hoses. Insert the 
flexi-hoses as how the indications on the 
handle are shown. (Left hole for Hot and 
Right hole for Cold)  

 

Fully screw threaded rod as shown. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
2.  Fit Tap 

 

Ensure the sink mounting hole for the tap is as 
per the rough-in dimensions. 

 

Ensure the Bottom ring is present underneath 
the tap. 

 

Carefully fit the flexible hoses and threaded rod 
through the sink hole as shown. 

Version 1, 2 December 2021, Page 2 of 9 

Ø30 MIN 
Ø38 MAX 

Rough-In Dimensions 

Bottom Ring 

Hot Inlet 

Cold Inlet 

Threaded rod 