1.6. Maintenance
1. Regularly check the connections between the power cord plug, the mains outlet and the PE (protective earth) wire.
2. In cold climate regions (below 0°), if the unit system is turned off for a long time, drain the DHW tank to prevent it from freezing and damaging the
heater.
3. If the DHW output parameters are sufficient, it is recommended to set a lower DHW temperature to reduce heat emission, prevent formation of water
scale and improve energy efficiency.
4. Clean the evaporator at least once a week.
5. Before turning off the unit for a long time, disconnect its power supply, empty the DHW tank and the DHW piping, and close all valves. Inspect the
condition of the unit's internal components.
6. Check the condensate drain pipe and clean it as necessary.
1.7. Unit inspection and handling
Upon delivery of your unit from the seller, inspect it for damage. If damage is found, immediately report it to the delivery carrier. Handling considerations:
1. The unit is fragile. Handle with care. Keep the unit upright to prevent damage of the compressor.
2. Before handling the unit, make sure that there are no obstacles on the way to the unit's installation site.
3. Handle the unit in its original packaging only.