background image

© All rights reserved - Galmet Sp. z o.o. Sp. K. 

Installation and Operating Manual / Warranty Card - SGW(S), SGW(S)B, SG(S)

5

2. Schemes

2.1. Exemplary connection scheme of the water heater in an open system

N -  collection vessel for an open system

Zb - safety valve*

Z1 -  shut off valve on cold water inlet

Z2 -  shut off valve on hot water outlet

Z3, Z4 -  shut off valve on water inlet from 

the heating system to the coil

Z5 -  shut off valve on water inlet from the 

heating system to the coil

O - water heater's housing

Ks - water outlet (drain)

C - circulation

GE - connection for the heating element

W. S. - spiral coil

Tr. - thermometer

Cz. - sensor cover

2.2. Exemplary connection scheme of the water heater in an closed system

N - expansion vessel

Zb1 - safety valve*

Zb2 - CH installation safety valve.*

Z1 -  shut off valve on cold water inlet

Z2 -  shut off valve on hot water outlet

Z3, Z4 -  shut off valve on water inlet 

from the heating system to 

the coil

Z5 -  shut off valve on water inlet from 

the heating system to the coil

O - water heater's housing

Ks - water outlet (drain)

C - circulation

GE - connection for the heating 

element

W. S. - spiral coil

Tr. - thermometer

Cz. - sensor cover

P - circulation pump

* not included

2. Schemes

Summary of Contents for SGW(S) Mini Tower 100

Page 1: ...S Tower vertical SGW S BigTower vertical SGW S BTowerBiwal vertical SG S vertical SGW S horizontal Type Cover Colour Spiral coils 100 120 140 200 250 300 400 500 700 800 1000 1500 skay artificial lea...

Page 2: ...heme of the SGW S Tower Slim 200 300 11 5 6 Technical specification of the SGW S Tower Slim 800 1000 12 5 7 Scheme of the SGW S Tower Slim 800 1000 13 5 8 Technical specification of the SGW S BTower B...

Page 3: ...tom on the heels of 5 4 200 500 l 2 700 1500 l Heaters are equipped with additional connections 3 4 capacity 100 140 l and 1 capacity 200 1500 l where you can install the drain valve In the SGW S B 20...

Page 4: ...The hose should be heat resistant up to 80 C with internal diameter of9mmandmax lengthof1 2m runtoadrainwithadowngrade min 3 inanenvironmentoftemperaturenotlowerthan0 C Thehosemustbe protected against...

Page 5: ...s housing Ks water outlet drain C circulation GE connection for the heating element W S spiral coil Tr thermometer Cz sensor cover 2 2 Exemplary connection scheme of the water heater in an closed sys...

Page 6: ...n the heating module 230V electrical scheme heater 2 3 kW grz grz grz L1 L2 L3 A1 A2 A3 B1 B2 B3 2 N PE 3 4 1 400V electrical scheme heater 4 5 9 kW 400V electrical scheme heater 12 24 kW 3 Troublesho...

Page 7: ...the electronic part and the anode is connected incorrectly Lack of contact between the ground tank and the electrical part of the anode The anode is contacted with the mass of the tank Fill the tank...

Page 8: ...Connections for the SGW S 100 400 700 1000 water heaters h1 Coldwaterinlet G mm 210 165 165 1 210 1 210 1 130 1 240 6 4 215 6 4 250 h2 CHwateroutflow G mm 310 250 250 1 290 1 285 1 280 1 320 1 375 1...

Page 9: ...Warranty Card SGW S SGW S B SG S 9 5 3 Scheme of the SGW S MiniTower 100 140 Tower 200 500 BigTower 700 1500 crk h3 h2 h1 h5 h4 SGW S 100 140 SGW S 200 250 400 crk h3 h2 h1 h5 h4 crk h3 h2 h1 h5 h4 SG...

Page 10: ...0 38x400 M8 screw 38x200 38x200 38x200 Connections for the SGW S Tower Slim 200 water heaters h1 Cold water inlet G mm 1 140 h2 CH water outflow G mm 1 225 h3 Sensor cover G mm 325 h4 Circulation G mm...

Page 11: ...o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 11 5 5 Scheme of the SGW S Tower Slim 200 300 h1 L h2 h3 h4 h5 h6 h1 L h2 h3 h4 h5 h6 SGW S Tower Slim 200 I SGW S Tower Slim...

Page 12: ...MPa 1 6 1 6 Coil surface m2 2 4 3 7 Coil power 70 10 45 C kW 44 5 60 Efficiency l h 1099 1468 Magnesium anode 2 plug 38x600 38x600 5 4 plug 38x400 38x400 Connections h1 Cold water inlet G mm 6 4 210...

Page 13: ...rights reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 13 5 7 Scheme of the SGW S Tower Slim 800 1000 SGW S Tower Slim 800 1000 5 Technical specificat...

Page 14: ...1 375 1 450 h3 Sensor cover I G mm R 3 8 355 R 3 8 400 R 3 8 435 R 3 8 570 R 3 8 575 R 3 8 590 crk Circulation G mm 450 595 650 770 5 4 925 5 4 880 h4 Hot water inflow from solar collector G mm 1 550...

Page 15: ...ating Manual Warranty Card SGW S SGW S B SG S 15 5 9 Scheme of the SGW S BTower Biwal 200 1500 crk h3 h2 h1 h5 h6 h7 h8 h4 crk h3 h2 h1 h5 h6 h7 h8 h4 SGW S B 200 300 700 1000 SGW S B 250 400 SGW S B...

Page 16: ...W 24 24 43 48 Additional source coil s power 70 10 45 C kW 24 24 24 24 Dimensions h1 Cold water inlet G mm 1 130 1 130 1 160 1 160 h2 Coil return I G mm 1 210 1 180 1 240 1 240 h3 Coil return II G mm...

Page 17: ...BTower Biwal Max 200 500 with two spiral coils at the bottom part of the tank d D h7 h5 h3 h2 0 h4 h6 L h8 h9 d D h7 h5 h3 h2 h1 0 h4 h6 L h8 h9 SGW S BTower Biwal Max 200 with two spiral coils at th...

Page 18: ...SGW S BTower Biwal Slim 200 water heaters h1 Cold water inlet G mm 1 140 h2 Water outflow to solar collector G mm 1 225 h3 Sensor cover I G mm 325 h4 Circulation G mm 1 485 h5 Hot water inflow from so...

Page 19: ...and Operating Manual Warranty Card SGW S SGW S B SG S 19 5 13 Scheme of the SGW S BTower Biwal Slim 200 300 h1 L h2 h3 h4 h5 h6 h7 h8 h9 h1 L h2 h3 h4 h5 h6 h7 h8 h9 SGW S BTower Biwal Slim 200 I SGW...

Page 20: ...CH coil s surface m2 1 2 1 8 CH coil s power 70 10 45 C kW 24 5 39 CH coil s efficiency l h 600 958 Magnesium anode 2 plug 38x600 38x600 5 4 plug 38x400 38x400 Connections h1 Cold water inlet G mm 6...

Page 21: ...reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 21 5 15 Scheme of the SGW S BTower Biwal Slim 800 1000 SGW S BTower Biwal Slim 800 1000 5 Technical sp...

Page 22: ...570 h6 DHW outflow Gw 3 4 mm 790 920 1070 Connections for the SG S 200 400 tanks h1 Water drain Gw 1 mm 130 160 h2 Cold water inlet Gw 1 mm 210 240 h3 Sensor cover I Gw 1 2 mm 440 570 h4 Sensor cover...

Page 23: ...reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 23 5 17 Scheme of the SG S 100 500 SG S 100 140 SG S 200 400 SG S 300 500 h1 h2 h3 h4 h5 5 Technical sp...

Page 24: ...plug 38x200 38x400 38x400 Connections h1 Cold water inlet Gw 6 4 mm 250 270 270 h2 Additional source inlet Gw 6 4 mm 360 380 380 h3 Sensor cover I Gw 1 2 mm 650 600 600 h4 Additional source inlet Gw 6...

Page 25: ...All rights reserved Galmet Sp z o o Sp K Installation and Operating Manual Warranty Card SGW S SGW S B SG S 25 5 19 Scheme of the SG S 700 1500 SG S 700 1500 5 Technical specification...

Page 26: ...45 C kW 23 24 24 Efficiency l h 560 570 570 Coil power 80 10 45 C kW 30 4 32 32 Efficiency l h 740 760 760 Demand for heating water from CH boiler m3 h 2 6 2 9 2 9 Magnesium anode 5 4 plug 25x390 38x2...

Page 27: ...w ownica spi Typ Jedn SGW S poziomy 140 S pozi Pojemno l 140 Max ci nienie pracy zbiornika MPa Max ci nienie w ownicy MPa Pow wymiennika do c o m2 0 95 Moc wymiennika do c o 70 10 450 C kW 23 Wydajno...

Page 28: ...W The wall thickness of the jackets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thi...

Page 29: ...l as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thickness SGW S MiniTower 100 400 2 0 S235JR 2 2 S235JR SGW S...

Page 30: ...ets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Bottoms Material Jackets Material Material thickness Material thickness SGW S BTower Biwal Slim 2...

Page 31: ...Tower Slim ErP class C 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identifier SGW S SLIM 200 SGW S SLIM 250 SGW S SLIM 300 3 EN Energy efficiency class C C C 4 EN Standing loss W 7...

Page 32: ...A A 4 EN Standing loss W 42 46 48 5 EN Storage volume L 199 240 286 7 8 SGW S BTower Biwal Max 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identifier SGW S Bd 200 SGW S Bd 300 SGW...

Page 33: ...leddirectlyinfrontoftheheateronthepipesupplyingitwithcoldwater Onlyvalvesacceptablebyadequateorgansshould beused adjustedtostoragewaterheaters Safetyvalveshouldbeusedaccordingtotheoperatingmanualforth...

Page 34: ...methodforrepairshallbespecifiedbythemanufacturer 21 Multiple repairs will not include the following heater adjustment replacement of magnesium anode replacement of gaskets nor any element wearing duri...

Page 35: ...f repair Service s seal Service s seal Service s seal Service s seal Owner s name and address Owner s name and address Owner s name and address Owner s name and address Owner s signature Owner s signa...

Page 36: ...Installation confirmation Type Factory no Date of sale Seller s stamp and signature Warranty coupon 1 Warranty coupon 2 Warranty coupon 3 Warranty coupon 4 Type Type Type Type Factory no Factory no Fa...

Reviews: