4. Technical specification
4.20. Technical parameters - SG(B) 500 with the maximum size spiral coil
Type SG(B)
unit
SG(B) 500
Storage capacity
*
l
459
Tank’s maximum working temperature
°C
95
Tank’s maximum working pressure
bar
3
Coil's maximum working pressure
bar
6
Coil's surface
m
2
7,5
Dimensions
CH boiler water connection height
GS1 mm
265
Coil return connection height
GS2 mm
275
Heater connection height
GS3 mm
430
CH boiler water connection height
GS4 mm
495
Sensor cover or thermometer connection height GS5 mm
575
CH boiler water connection height
GS6 mm
950
Sensor cover or thermometer connection height GS7 mm
1015
Sensor cover or thermometer connection height GS8 mm
1395
CH boiler water connection height
GS9 mm
1405
Coil feeding connection height
GS10 mm
1545
CH boiler water connection height
GS11 mm
265
CH boiler water connection height
GS12 mm
730
CH boiler water connection height
GS13 mm
1195
CH boiler water connection height
GS14 mm
1635
Height
L
mm
1950
External diameter (without insulation)
d
Ø
630
External diameter (with insulation)
D
Ø
755
Insulation (polyurethane foam)
mm
60
External housing
-
skay
Connections
CH boiler water inflow / CH boiler water outflow
Gw
6/4"
Sensor cover or thermometer
Gw
½"
Coil feeding / Coil return
Gw
5/4"
Heater connection
Gw
6/4"
Venting
Gw
6/4"
Water drain
Gw
1"
Weight without insulation (empty)
kg
280
*