© All rights reserved - Galmet Sp. z o.o. Sp. K.
Installation and operation manual of the SG(B) buffers
23
4. Technical specification
4.18. Technical parameters - SG(B) 400 with the maximum size spiral coil
Type SG(B)
unit
SG(B) 400
Storage capacity
*
l
366
Tank’s maximum working temperature
°C
95
Tank’s maximum working pressure
bar
3
Coil's maximum working pressure
bar
6
Coil's surface
m
2
6,0
Dimensions
CH boiler water connection height
GS1 mm
250
Coil return connection height
GS1 mm
250
CH boiler water connection height
GS2 mm
450
Sensor cover or thermometer connection height GS3 mm
780
CH boiler water connection height
GS4 mm
865
CH boiler water connection height
GS5 mm
1270
Coil feeding connection height
GS6 mm
1400
Heater connection height
GS7 mm
340
CH boiler water connection height
GS8 mm
660
CH boiler water connection height
GS9 mm
1065
Sensor cover or thermometer connection height GS9 mm
1065
CH boiler water connection height
GS10 mm
1470
Sensor cover or thermometer connection height GS10 mm
1470
Height
L
mm
1750
External diameter (without insulation)
d
Ø
600
External diameter (with insulation)
D
Ø
700
Insulation (polyurethane foam)
mm
45
External housing
-
skay
Connections
CH boiler water inflow / CH boiler water outflow
Gw
6/4"
Sensor cover or thermometer
Gw
½"
Coil feeding / Coil return
Gw
5/4"
Heater connection
Gw
6/4"
Venting
Gw
6/4"
Water drain
Gw
1"
Weight without insulation (empty)
kg
238
*