7
1 GENERAL INFORMATION
The manual is meant to familiarize the user with the operation of a solid fuel boiler.
Every user should read the manual for the boiler and controller before installation and
use. It contains recommendations for proper handling and use of the boiler. Failure to
comply with the rules and guidelines presented in this manual releases the boiler
manufacturer from all liability and warranty obligations. Boilers are equipped with a
thermometer and, optionally, a draught regulator, or a fan and an electronic "LUKSUS"
controller, which controls the operation of the boiler (fan and pumps installed in the
heating system). The boiler should be operated only by an adult. A complete cleaning of
the boiler should be done at least once a month during the heating season. The boilers
are built with a fixed
water-cooled grate
- KWR, and a removable
cast iron grate
-
KW. Satisfaction with the use of the boiler can be achieved only when appropriate fuel
with a high calorific value and adequate granulation is used.
1.1 Application
Steel boilers of the GT-KW, GT-KWR, GT-KWRU, GT-KWRUZ types are
intended for heating single-family houses equipped with hydronic central
heating
of an open type system
with
gravitational or forced circulation. The
system, within which the boiler operates, must be equipped with safety features
in accordance with the requirements of the PN-91/B-02413 standard, with a
maximum operating temperature of 95°C. Boilers are not subject to registration
with the district Technical Inspection Office.
Selecting boiler power depending on the insulation of the building
Boiler type
Room height
[m]
Room surface area
[m
2
]
Room cubic capacity
[m
3
]
KW - 7
2.5
48
÷
70
120
÷
175
KW - 10
2.5
68
÷
100
170
÷
250
KWR - 11
2.5
74
÷
110
185
÷
275
KW - 15
2.5
106
÷
150
255
÷
375
KWR - 17
2.5
116
÷
170
290
÷
425
KW - 20
2.5
136
÷
200
340
÷
500
KWR
– 22
2.5
150
÷
220
375
÷
550
KWRUz
– 22
2.5
150
÷
220
375
÷
550
KWR - 25
2.5
166
÷
250
415
÷
625
KWR - 27
2.5
180
÷
270
450
÷
675
KWRU - 37
2.5
270
÷
370
675
÷
925
KWRU - 50
2.5
370
÷
500
925
÷
1250
KWRU - 60
2.5
400
÷
600
1000
÷
1500
KWRUz-70
2.5
470
÷
700
1175
÷
1750
KWRU - 99
2.5
700
÷
1000
1700
÷
2500
(for demand for heat equal to
60
–
40
W/m
3
)