background image

MAKING MODERN LIVING POSSIBLE

Installation Guide

DWH

www.heating.danfoss.com

Summary of Contents for DWH 200

Page 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide DWH www heating danfoss com...

Page 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Page 3: ...ion 11 3 1 2 Connections and dimensions 12 3 1 3 Installation 12 3 1 4 Positioning 12 3 1 5 Piping installation 12 3 2 Maintenance 13 3 2 1 Safety valve 13 3 2 2 Water quality 14 3 2 3 Sensor 14 3 2 4...

Page 4: ...ions and dimensions 1 1 Connections and dimensions 455 596 690 40 10 1 2 3 4 5 6 H Fig 1 1 455 596 690 40 10 H 1 2 3 4 5 6 Fig 2 2 118 Fig 3 3 118 Fig 4 4 Installation Guide DWH 02 Danfoss Heating Sol...

Page 5: ...5 91 87 85 96 1 85 19 85 85 50 100 111 94 80 13 12 121 122 80 83 10 11 150 86 1905 1620 MBH 300 MBH 200 H MBH 200 Fig 6 6 Installation Guide DWH Danfoss Heating Solutions VMBNB82J 5...

Page 6: ...ir mycket h g kr vs att en blandningsventil installeras mellan kallvatten och varmvattenlednin garna som s kerst ller en l gre temperatur p tappvattnet N Se till att r rinstallationen utf rs i enlighe...

Page 7: ...sningen 90 moturs H ll samtidigt emot frontpl ten med handen 2 Luta frontpl ten ut t 3 Lyft frontpl ten upp t f r att lossna den fr n varmvattenberedaren 2 1 4 Placering Placera Danfoss DWH p ett golv...

Page 8: ...S kerhetsventilens spilledning ska st i oavst ngbar f rbindelse med avlopp och mynna synligt ver detta i frostfri milj 2 2 Sk tsel 2 2 1 S kerhetsventil S kerhetsventilen r ett skydd mot vertryck i d...

Page 9: ...anl ggnin gen En vattenanalys ger besked om eventuellt n dv ndiga tg rder 2 2 3 Givare Monteras Danfoss DWH i kombination med DDHP L Opti eller DHP L Opti Pro DHP L Opti Pro skall givarna NTC typ som...

Page 10: ...tsel r Danfoss V rmepumpar tagande enligt g llande garantibest mmelser ej bindande Danfoss V rmepumpar f rbeh ller sig r tten till ndringar i detaljer och specifikationer utan f reg ende meddelande In...

Page 11: ...Pro and DHP L Opti Pro DHP L Opti Pro becomes extremely hot a mixer valve must be installed between the cold water and hot water pipes to ensure a lower domestic hot water temperature N It is importan...

Page 12: ...he catch 90 anticlockwise 2 At the same time hold the front cover with one hand 3 Lift the front cover upwards to remove it from the hot water heater 3 1 4 Positioning Position Danfoss DWH on a floor...

Page 13: ...connection with the outlet and visibly flow into it in a frost free environ ment 3 2 Maintenance 3 2 1 Safety valve The safety valve is protection against the over pressure in the closed hot water tan...

Page 14: ...er analysis will provide indication of any necessary re medial actions 3 2 3 Sensor If Danfoss DWH is installed in combination with DHP L Opti or DHP L Opti Pro DHP L Opti Pro the sensors NTCtype in t...

Page 15: ...ser This document is an integral and essential part of the product It should be kept with the appliance so that it can be consulted by the user and our authorised personnel Please read carefully the i...

Page 16: ...f and contact the installer WARNING TO THE INSTALLER Danger a This installation is subject to building regulation approval notify the Local Authority of intention to install Danger b Use only manufact...

Page 17: ...Cold water 13 Hot water 18 Water heater DWH 80 Shut off valve 83 Non return valve 86 Safety valve expansion heating system 1 5 bar 87 Safety valve cold water 9 bar included in delivery 89 Vacuum valve...

Page 18: ...Arrangement N No valve should be fitted between the safety relief valve and the stor age cylinder Discharge pipe arrangement N The tundish must be positioned away from any electrical devices N The tun...

Page 19: ...the tap water system shall be flushed out and re filled How to drain the tap water system After the tap water system has been flushed out the cold and hot water pipes and the water heater tank need to...

Page 20: ...Bereiter ist so an einen Ausdehnungsbeh lter und ein Sicherheits ventil anzuschlie en dass diese Verbindung nicht abgesperrt werden kann N Die maximal im DWH Bereiter zugelassene Temperatur betr gt s...

Page 21: ...Abbildung 2 Zeichenerkl rung 1 R cklaufleitung zur W rmequelle 22 mm 2 Warmwasser 22 mm 3 Kaltwasser 22 mm 4 Zufluss von W rmequelle 22 mm 5 Durchf hrungen 6 Entl ftung Warmwasserbereiter DWH 200 DWH...

Page 22: ...00 50 Au enf hler 80 Absperrventil 83 R ckschlagventil 85 Entl ftungventil 86 Sicherheitsventil Ausdehnung Heizungssystem 1 5 bar 87 Sicherheitsventil Kaltwasser 9 bar im Beipackkarton enthalten 89 Va...

Page 23: ...alit t Die indirekte Erw rmung des Brauchwassers ist ein Vorzug durch den sich Danfoss DWH f r Gegenden mit besonders kalkhaltigem Wasser eignen Bei Installationen in denen das Wasser aus einem Brunne...

Page 24: ...eim Betrieb und bei der Wartung nicht befolgt sind die Verpflichtungen von Danfoss gem der g ltigen Garantiebestimmungen nicht bindend Danfoss beh lt sich das Recht auf nderungen an Details und Spezif...

Page 25: ...Installation Guide DWH Danfoss Heating Solutions VMBNB82J 25...

Page 26: ...Installation Guide DWH VMBNB82J Danfoss Heating Solutions 26...

Page 27: ...Installation Guide DWH Danfoss Heating Solutions VMBNB82J 27...

Page 28: ...erves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specific...

Reviews: