8

MB SERIES

Installation:

To insure proper operation and to avoid potential 

safety  hazards,  place  the  unit  on  a  firm,  level 

surface.

Ventilation:

Make  certain  that  proper  space  is  provided  for 

ventilation.  Never  block  the  fan  vent  holes 

located  on  the  sides  of  the  amplifier.  If  the 

amplifier  will  be  installed  in  a  rack  or  other 

enclosed area, make sure that there is sufficient 

air  movement  within  the  enclosure  to  allow 

proper  cooling.  Consult  your  dealer  for  more 

information. Avoid installation in extremely hot 

or cold locations, and areas that are exposed to 

direct sunlight, or near heating equipment. Avoid

moist or humid locations.

Remember, power amplifiers generate heat. The 

ventilation slots on the enclosure are specifically 

designed  to  remove  this  heat.  Blocking  or 

placing other electronic equipment near the heat 

dissipation  system  may  possibly  affect  the 

long-term reliability of both your amplifier and 

the other equipment.

Moving the Unit: 

Before moving the unit, be certain to disconnect 

any  interconnection  cords  with  other 

components, and make sure that you disconnect 

the unit from the AC outlet. 

Cleaning:

When the unit gets dirty, clean only with a dry 

cloth.  Never  use  benzene,  thinner,  alcohol,  or 

other  volatile  cleaning  agents.  Do  not  use 

abrasive cleaners, as they may damage the finish 

of metal parts. Avoid spraying insecticides near 

the unit. 

Maintenance:

Your new amplifier is rugged. It was built to give 

you a lifetime of trouble-free operation, if it is 

operated  in  accordance  with  the  instructions 

contained in this manual. The only maintenance 

required  is  cleaning.  If  you  are  going  to  move 

your  amplifier  around  frequently,  we 

recommend  a  road  case  to  protect  it  from 

scratches and road wear. 

Packaging:

The carton and packing materials used in shipping

your new amplifier were specifically designed  to

cushion it from the shocks and vibration that occur

during transport. We suggest that you save the

carton and packing materials for use in shipping, in

the event you move, or the amplifier  needs repair.

Summary of Contents for MB200

Page 1: ...MB 200 OWNER S MANUAL ...

Page 2: ...ntact your local dealer or GK as soon as possible Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com We wish you a lifetime of good playing and remember to always have fun GK Philosophy I have never seen the point in doing things the way others have done them I also have not been very interested in...

Page 3: ...UR EVITER LES CHOCS ELECTRIQUES INRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSER JUSQU AU FOND Table Of Contents Safety Information __________________________ Pg 4 Quick Start ________________________________ Pg 5 Front Panel Controls ________________________ Pg 6 Sound Tips ________________________________Pg 7 Installation and Maintenance ____________...

Page 4: ... Power Cord To avoid safety hazards use only the power cord supplied with your unit If a replacement cord is needed make certain to use a standard IEC compliant cord Damaged power cords should be replaced immediately When setting up make certain thattheACplugiseasilyaccessible Ifyoudo not intend to use the amplifier for a considerable length of time disconnect the plug from the AC Mains Socket Do ...

Page 5: ...s noted below Maximum Recommended Speaker Loads One 4 Ohm or two 8 Ohm cabinets 3 Initial front panel control settings Set all EQ controls and contour knob to 12 o clock Set the input volume controls at 0 4 Plug in your bass Using an instrument shielded cable connect your bass to the Input jack and press the power switch on If you have active tone controls on your bass turn all of the controls to ...

Page 6: ... used to control the low end push turned up Power Switch Turns the amplifier on and off In the on position the ring surrounding the button will light red during power up then changes to blue indicating the amp is ready for normal operation Should the amp experience a fault over heat or over current the amp will mute and the ring will light red until the condition is corrected This LED turns off wh...

Page 7: ...ed for midrange clarity at higher playing levels Direct Out The MB Series provides a low noise high quality balanced direct output for connection to PA and recording consoles A ground lift switch is included to remove hum and buzz when connecting to equipment powered by a different ground system With the pre post EQ switch set to pre out the direct output signal is fed directly from the input stag...

Page 8: ... and the other equipment Moving the Unit Before moving the unit be certain to disconnect any interconnection cords with other components and make sure that you disconnect the unit from the AC outlet Cleaning When the unit gets dirty clean only with a dry cloth Never use benzene thinner alcohol or other volatile cleaning agents Do not use abrasive cleaners as they may damage the finish of metal par...

Page 9: ... control all the way up the low end is slightly boosted the mids are dropped and the high end is pushed up This is only found in GK amplifiers Cool Running Reliability To cool the amp when its being driven hard we ve designed a temperature sensitive fan cooling system When the amp is under a light load the fan is off or running at a low speed reducing fan noise As the amp works harder the fan spee...

Page 10: ... Bass Lo Mid Hi Mid Treble Voicing Filters Contour 140W 8 Ohms 200W 4 Ohms 0 6V Rms 1 6V Rms 1M Ohms 500 Ohms 100K Ohms 10dB 60Hz 6dB 10dB 250Hz 6dB 10dB 1KHz 14dB 7KHz 2dB 50Hz 10dB 500Hz 3dB 7 KHz Noise 90 dB reference to 200W 140W A Weighted Amplifier Protection Full short circuit thermal and RF protection Stable into reactive and mismatch loads Five second muted warm up Cooling Variable speed ...

Reviews: