RG66001652_REV.02
41
LCW - LCR
Technical data
Performance data – heat pump models LCW-H
Model
LCWH130 LCWH150 LCWH180 LCWH205 LCWH235 LCWH250 LCWH275 LCWH300
Refrigerant
R407C R407C R407C R407C R407C R407C R407C R407C
Cooling capacity (1)
[kW]
134.6 147.8 169.4 205.4 231.9 248.9 268.1 290.2
Heating capacity (2)
148.7 163.4 187.2 227.0 256.2 274.9 296.1 320.6
Rated electrical input
[kW]
34.1 37.6 44.2 53.4 60.1 65.4 69.3 74.9
Rated current absorption
[A]
58.7 64.1 78.5 91.6 104.1 112.4 117.9 126.9
Maximum current
absorption
[A]
123.2 141.2 144.2 165.6
205.6 228 246 260
Inrush current
[A]
307 325.3 248 301 318 377 384 384
Evaporator water flow rate
[l/h]
23151 25428 29149 35344 39894 42803 46108 49920
Pressure drop – evaporator
side
[kPa]
41.7 43.1 53.8 37.7 35 36.3 40.4 40.4
Condenser water flow rate
(1)
[l/h]
13810 15183 17492 21193 23907 25722 27617 29886
Pressure drop – condenser
side
[kPa]
41.6 50.4 61.5 32.9 37.4 46.1 54.9 54.9
Additional pressure drop
for condensation control
(optional)
[kPa]
37.2 46.1 39.5 46.0 26.4 32.9 37.3 37.3
Compressor type
[-]
Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Number of cooling circuits
[-]
2 2 2 2 2 2 2 2
Number of compressors
[-]
2 2 4 4 4 4 4 4
Oil charge/ compressor
[dm3]
8 8 8 8 8 8 8 8
Evaporator [type]
BPHE BPHE BPHE BPHE BPHE BPHE BPHE BPHE
Number of evaporators
1 1 1 1 1 1 1 1
Condensers [type]
BPHE BPHE BPHE BPHE BPHE BPHE BPHE BPHE
Number of condensers
1 1 1 1 1 1 1 1
Water content in user
section
[dm3]
9.05 10.05 10.05 11.05 12.04 12.04 13.06 14.04
Type of water connections
Victaulic Victaulic Victaulic Victaulic Victaulic Victaulic Victaulic Victaulic
Size of water connections
3" 3" 3" 4" 4" 4" 4" 4"