8
WC66000067-REV.00
All copying, even partial, of this manual is strictly forbidden
CSW
8
HYDRAULIC CONNECTIONS
Position and diameter are reported as shown in the picture below.
When a piping is connected to the unit main body or removed from it, be sure to use two wrenches to fasten it.
Carefully insulate pipes, valve assemblies and coil connections to avoid condensation forming on the pipes and dripping on the false ceiling.
MODELS
water inlet
water outlet
CSW 136
3/4"
3/4"
CSW 186
3/4"
3/4"
CSW 246
3/4"
3/4"
CSW 249
3/4"
3/4"
CSW 369
1"
1"
CSW 489
1"
1"
7
SOUND LEVELS
Vr
Fan speed:
3
=maximum
2
=medium
1
=minimum
Lw
Octave band sound power level
Lw
A
A - weighted sound power level
Lp
A
A - weighted sound pressure level (1m distance, 4 directional factor)
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
LwA
LpA
dB
dB
dB
dB
dB
dB
dB
dB/A
dB/A
max
50,3
50,1
47,7
43,3
38,4
28,4
18,8
49,0
44
med
40,2
42,1
38,8
32,9
29,7
17,5
17,7
40,0
35
min
32,6
34,0
30,9
22,7
26,8
15,8
16,9
33,0
28
max
54,7
53,5
52,3
47,7
41,9
32,1
22,8
53,0
48
med
44,8
44,3
41,9
36,1
31,5
18,6
17,8
42,0
37
min
36,8
36,2
31,8
23,2
25,8
15,4
16,7
33,0
28
max
57,5
60,3
59,5
55,7
50,3
43,7
34,0
61,0
56
med
53,9
51,2
50,4
45,8
38,9
29,0
20,8
51,0
46
min
42,0
43,9
42,0
36,1
29,8
17,5
18,0
42,0
37
max
58,8
54,8
50,2
46,7
50,0
31,9
19,7
55,0
50
med
53,1
49,3
45,9
44,5
45,6
26,8
18,0
51,0
46
min
49,8
46,7
42,6
43,2
40,0
21,4
17,7
47,0
42
max
57,5
57,9
52,7
49,3
54,4
42,7
30,0
58,0
53
med
54,0
53,4
49,7
46,3
52,1
36,5
23,6
55,0
50
min
54,0
50,3
46,6
44,2
49,7
32,1
20,3
53,0
48
max
63,4
66,0
53,8
50,7
52,3
42,9
32,5
60,0
55
med
59,6
62,6
51,3
47,7
50,5
37,5
26,3
57,0
52
min
56,9
61,0
48,8
45,4
48,6
33,5
22,8
55,0
50
CSW 369
CSW 489 - CSW 489DF
Lw
Vr
CSW 136 - CSW 136DF
CSW 186
CSW - CSW DF
CSW 246 - CSW 246DF
CSW 249 - CSW 249DF
CSW 136-186-246
CSWDF 136-246
drain outlet pipe
air purge
water outlet
water inlet
drain valve
drain outlet pipe
air purge
water outlet
water inlet
drain valve
drain outlet pipe
air purge
water outlet
water inlet
drain valve
drain outlet pipe
air purge
water outlet
water inlet
drain valve
CSW 249-369-489
CSWDF 249-489
MODELS
chilled water
chilled water
hot water
hot water
inlet
outlet
inlet
outlet
CSW 136 DF
3/4"
3/4"
1/2"
1/2"
CSW 246 DF
3/4"
3/4"
1/2"
1/2"
CSW 249 DF
3/4"
1/4"
1/2"
1/2"
CSW 489 DF
1"
1"
3/4"
3/4"
Summary of Contents for CSW Series
Page 1: ...GB CSW water cassette technical manual...
Page 18: ...18 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW...
Page 19: ...19 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW...
Page 20: ...40010 Bentivoglio BO Via Romagnoli 12 a Tel 051 8908111 Fax 051 8908122 www galletti it...