background image

10

WC66000067-REV.00

All copying, even partial, of this manual is strictly forbidden

CSW

CSW 249

CSWDF 249

drain outlet pipe

drain outlet pipe

outlet 1"

inlet 1"

outlet 1"

inlet 1"

outlet 1"

inlet 1"

9

DIMENSIONS

Summary of Contents for CSW Series

Page 1: ...GB CSW water cassette technical manual...

Page 2: ...ensate present in the drip tray ELECTRICALCOMPONENTS Timer for the drainage pump Electrical connection board to the wall mounted panel for the automatic control of the water cassette and water regulat...

Page 3: ...56 0 65 High m3 h 550 710 870 1140 1380 1610 Med m3 h 420 520 630 890 1140 1290 Low m3 h 240 260 340 770 850 1010 High dB A 49 53 61 55 58 60 Med dB A 40 43 51 51 55 57 Low dB A 33 33 42 47 53 55 Gri...

Page 4: ...13 CSW 489 Max 8510 6500 1458 26 7510 6100 1288 21 6430 5690 1103 16 4820 4230 827 17 CSW 489 Med 7410 5500 1271 20 6530 5140 1121 16 5570 4760 955 12 5320 4960 913 10 CSW 489 Min 6490 4640 1113 16 57...

Page 5: ...10 2670 534 4 2400 2400 412 2 CSW 489DF Max 8210 6550 1409 9 7240 6180 1243 8 6170 5790 1058 6 4830 4830 830 4 CSW 489DF Med 7190 5570 1234 7 6320 5230 1085 6 5330 4860 915 4 4190 4190 720 3 CSW 489DF...

Page 6: ...1067 7 6840 595 3 9660 845 5 12360 1084 7 CSW 489 Max 8440 1468 22 9220 803 8 13170 1151 14 17040 1496 21 CSW 489 Med 7660 1333 19 8410 732 7 11990 1047 12 15460 1357 18 CSW 489 Min 6440 1120 14 7080...

Page 7: ...249DF Min 2760 479 6 2740 239 2 4260 372 4 5630 494 6 CSW 489DF Max 4750 826 7 4810 419 2 7340 641 4 9700 851 7 CSW 489DF Med 4150 721 5 4160 362 2 6410 560 3 8460 742 5 CSW 489DF Min 3630 631 4 3610...

Page 8: ...5 18 6 17 8 42 0 37 min 36 8 36 2 31 8 23 2 25 8 15 4 16 7 33 0 28 max 57 5 60 3 59 5 55 7 50 3 43 7 34 0 61 0 56 med 53 9 51 2 50 4 45 8 38 9 29 0 20 8 51 0 46 min 42 0 43 9 42 0 36 1 29 8 17 5 18 0...

Page 9: ...9 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW drain outlet pipe drain outlet pipe CSW 136 186 246 CSWDF 136 246 9 DIMENSIONS...

Page 10: ...WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW CSW 249 CSWDF 249 drain outlet pipe drain outlet pipe outlet 1 inlet 1 outlet 1 inlet 1 outlet 1 inlet 1 9 DIMENSIO...

Page 11: ...C66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW CSW 369 489 CSWDF 489 outlet 1 inlet 1 drain outlet pipe drain outlet pipe outlet 1 inlet 1 outlet 1 inlet 1 9 DIMENS...

Page 12: ...valve and KP power interface to control up to 4 units with 1 control panel diagram 5 CSWDF with MICROPROD control panel SW probe VK valves and KP power interface to control up to 4 units with 1 contr...

Page 13: ...13 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW 1 CSW 136 186 246 CSWDF 136 246 CSW 249 369 489 CSWDF 249 489 10 WIRING DIAGRAMS...

Page 14: ...is manual is strictly forbidden CSW SW SA RM EX EX RM V RE N 6 5 4 230 1 50 MICROPRO D V2 PE V1 N L V3 L N F 2 3 1 N L VHC IL CSW SW SA VC RM EX EX RM V RE N 6 5 4 230 1 50 MICROPRO D V2 PE V1 N L V3...

Page 15: ...3A 250V RELE DI POTENZA POWER RELAY 3A 250V 13 L 14 N 15 L 16 N 2 3 4 5 C 1 2 3 1 2 3 4 KP 32 33 31 34 27 28 29 30 23 24 25 26 19 20 22 21 L N IL F 230V 1 50Hz RHC RM RM MICROPRO RM RM CRHC MICROPROD...

Page 16: ...WER RELAY 3A 250V 13 L 14 N 15 L 16 N 2 3 4 5 C 1 2 3 1 2 3 4 KP 32 33 31 34 27 28 29 30 23 24 25 26 19 20 22 21 L N IL F 230V 1 50Hz RHC RM RM MICROPRO RM RM CRHC MICROPROD EXT K VC K VH SW 3 2 1 N L...

Page 17: ...ble the unit operation terminals for the connections with external signals in order to enable or disable the unit operation terminals for the connections with external signals in order to enable or di...

Page 18: ...18 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW...

Page 19: ...19 WC66000067 REV 00 All copying even partial of this manual is strictly forbidden CSW...

Page 20: ...40010 Bentivoglio BO Via Romagnoli 12 a Tel 051 8908111 Fax 051 8908122 www galletti it...

Reviews: