EN - 34
Cleaning the dust container, micro-filter and HEPA filter
After approx. 5 emptying of the container we recommend carrying out a complete cleaning
of the filtration system from settled dust. Do this following these steps:
–
Press the container arrest button
A6
and pull the container
B
out of the vacuum cleaner
(pic. 12A).
–
Grab the body of the container B with one hand and turn the container lid
B5
counter -
clockwise (in the direction of the opened lock) with moderate strength, see pic. 12B.
– Then remove the HEPA filter B3 with the filtration cover of the HEPA filter B4 from the lid
by turning slightly counter-clockwise (direction of the open lock), see pic. 12C.
–
Finally, slide up the filtration cover of the HEPA filter B4 from the HEPA filter B3, see pic. 12D
–
HEPA filter
B3
: Tap the dust out of the filter over a dustbin or to clean the filter through
a blowing (we recommend the filter cleaning outside of living area for
hygiene reasons).
Outlet microfilter
Press the closure in the top part of the exhaust cover
A9
, fold the cover up and remove
from the cleaner (pic. 13). Pull out the microfilter
A8
. Put the properly cleaned (or new)
microfilter back into the cover reversely. Put the protrusions on the back cover into two
openings in the casing of the cleaner and close the cover with a click.
Clean all accessories
B
, the exhaust microfilter
A8
and suction micro-filter
A10
in lukewarm
running water with a cloth or a fine brush and let dry thoroughly. When all the parts have
dried completely, assemble them back reversely.
ATTENTION
– Do not use any aggressive washing or cleaning agents or hot water to clean the HEPA
filter and the micro–filter.
–
Cleaning the filter will not restore its original colour, but it will restore its filtration properties.
– The dust container is not resistant to cleaning in a dishwasher.
– The HEPA filter and the micro–filters are not intended for cleaning in a dishwasher.
– Proper insertion of micro–filters into the container will enable securing the mechanical
safety lock. Now you can put the container into the vacuum cleaner.
– The safety lock will not make it possible to put the container into the vacuum cleaner
if you forget to insert the micro–filters.
– Neglecting regular replacement of micro–filters can result in the vacuum cleaner defect!
– Make sure that the binding surfaces and sealing elements are functional.
– We recommend replacing the HEPA filter 2x a year. Replace the other filters if they
cannot be cleaned properly or if they are damaged. You can buy a spare HEPA filter and
micro-filters in the network of elektro shops.
!
Storing accessories
Accessories, floor nozzle, suction pipes and hose can be disassembled and stored
separately. Parking opening (protrusion) A4 on the back side of the cleaner can be used for
storing the assembled cleaner in a so-called parking position (obr. 14). For better stability,
slide individual parts of the tube to each other so that the tube is as short as possible. When
storing, always set the floor nozzle to the carpet position (i.e. with the brush retracted); thus
you will prevent bending of the bristles.