Gallagher T12 Manual Download Page 7

Page  7   

3E4720 Gallagher T12 Reader | Edi  on 12 | May 2023
Copyright © Gallagher Group Limited

4 Installa

Ɵ

 on

ATTENTION:

  This equipment contains components that can be damaged by 

electrosta  c discharge.  Ensure both you and the equipment are earthed before 
beginning any servicing.

The Gallagher T12 Reader is designed to be mounted on a standard Bri  sh electrical 

fl

 ush box, or any 

solid 

fl

 at surface.  However installa  on on metal surfaces, par  cularly those with a large surface area 

will reduce read range.  The extent to which the range is reduced will depend upon the type of metal 
surface.

Note:

  Considera  on should be given to the installa  on environment when using Bluetooth® enabled 

readers, as the read range may be reduced.

The recommended moun  ng height for the reader is 1.1 m (3.6   ) from the 

fl

 oor level to the centre of 

the reader device.  However this may vary in some countries and you should check local regula  ons for 
varia  ons to this height.

1. 

Ensure the building cable has been run out through the 

fl

 ush box.

If you are not moun  ng to a 

fl

 ush box, use the reader bezel as a guide to drill all 

fi

 ve holes.  Drill 

the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable 
will exit the moun  ng surface) and the four 

fi

 xing holes.

2. 

Run the building cabling out through the centre hole and through the reader bezel.

3. 

Secure the bezel to the 

fl

 ush box using the two M3.5 screws provided.  It is important the bezel 

of the reader is 

fl

 ush with and   ght against the moun  ng surface.

If you are not moun  ng to a 

fl

 ush box, secure the bezel to the moun  ng surface using the four 

fi

 xing screws provided.

Note: 

 It is strongly recommended that you use the screws provided.  If an alterna  ve screw is 

used, the head must be no larger nor deeper than that of the screw provided.

Note:

  Ensure the centre hole allows the cable to run freely out through the moun  ng surface, so 

that the reader facia can clip into the bezel.

Bezel

Building cable

M3.5 screw

M3.5 screw

4. 

Connect the reader tail extending from the facia assembly to the building cable.  Connect the 
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV 
Reader, as shown in the following diagrams.

Notes:

• 

Bluetooth® enabled readers must be connected as HBUS Readers.

• 

Gallagher High Sec readers must be connected as HBUS Readers. Gallagher High Sec 
reader connect to the Gallagher High Sec Controller 6000 (C305101) only.

Summary of Contents for T12

Page 1: ...d Gallagher T12 Reader Installa on Note T12 MIFARE Reader Black C300420 T12 MIFARE Reader White C300421 T12 Mul Tech Reader Black C300440 T12 Mul Tech Reader White C300441 High Sec T12 Reader Black C3...

Page 2: ...ss and it should not be relied on as such To the extent permi ed by law all express or implied or other representa ons or warran es in rela on to the informa on are expressly excluded Neither Gallaghe...

Page 3: ...oduct Codes Card Technologies Supported NFC Access for Android Supported From Bluetooth Access Supported From HBUS Comms Supported From Cardax IV Comms Supported From T12 MIFARE Reader C300420 C300421...

Page 4: ...2 3 Cabling The Gallagher T12 Reader requires a minimum cable size of 4 core 24 AWG 0 2 mm2 stranded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a s...

Page 5: ...vices HBUS Device Terminate HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termina on jumper RS485 1 T or Star circuits are not permi ed between...

Page 6: ...0 m 1640 200 m 650 450 m 1490 The matching of wire sizes to equivalent wire gauges are only approximate Recommended cable types for op mal HBUS RS485 performance Not applicable for Bluetooth enabled r...

Page 7: ...the 13 mm 1 2 inch diameter centre hole this is the centre hole for which the building cable will exit the moun ng surface and the four fixing holes 2 Run the building cabling out through the centre h...

Page 8: ...rdax IV Reader connec on Posi ve Red Nega ve Black HBUS Termina on Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue Cardax IV Reader 5 Fit the facia assembly into the bezel by clipping th...

Page 9: ...cess mode is Secure Flashes Green Access has been granted Flashes Red Access has been denied Flashes Blue Reading a Gallagher mobile creden al LED squiggle Cardax IV indica on 3 Flash Amber No communi...

Page 10: ...sing the default configura on for a reader in Command Centre Changing the configura on may vary the current value 5 The unpo ed variant C300440 01 does not have any environmental protec on 6 The unpo...

Page 11: ...perienced radio TV technician for help This device complies with Industry Canada licence exempt RSS standard s Opera on is subject to the following two condi ons 1 this device may not cause interferen...

Page 12: ...Gallagher Group Limited IMPORTANT This picture is not to scale therefore use the measurements provided 35 mm 1 38 26 mm 1 29 mm 1 14 86 mm 3 39 13 mm 1 2 diameter hole for cable 86 mm 3 39 25 mm 1 30...