English
Gallagher 3E4345 MB1000i MB1800i MB2800i Energizer User Manual
21
Save these instruc ons.
TROUBLESHOOTING
Problem
Causes
Solution
Energizer has started to run
slowly
The internal temperature of
the energizer is too high
Mount the energizer in a cool
area, out of direct sun and
with adequate ven la on
Displaying Error 11
Input voltage is too high
Check the input voltage of
your energizer
Displaying Error 12
Input voltage is too low
Check the input voltage of
your energizer
Displaying Error 14–19
Internal energizer fault
Turn energizer off for 30
seconds then turn back on. If
the error remains return the
energizer to your Gallagher
dealer for servicing.
Displaying Error 21
Dead zone
Check that the zone device
is connected and working
correctly.
Energizer output voltage is
low
There is a fault on the fence
Remove any excess grass
growth or short circuits on
the fence.
Earth voltage is too high
Earth system is inadequate
Check connec ons to the
earth system. Add extra
earth stakes.
No output and display shows
( - - )
Energizer is in standby mode Exit standby mode by
pressing the standby bu on
on the controller
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT
This symbol on the product indicates that this product, packaging and with special
care of the ba ery must not be disposed of with other waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a designated
collec on point for the recycling of waste electrical and electronic equipment. The
separate collec on and recycling of your waste equipment at the me of disposal
will help conserve natural resources and ensure that it is recycled in a manner that
protects human health and the environment. For more informa on about where
you can drop off your waste equipment for recycling, please contact your local city
recycling offi
ce or the dealer from whom you purchased the product.