English
Gallagher 3E4345 MB1000i MB1800i MB2800i Energizer User Manual
13
Current Display
The output current indicates how hard your energizer is working. When your fence
is in good condi on this reading will be low, typically under 15 Amps. As the load
on the fence increases the current will rise and output voltage will fall. The output
current will typically change with fence condi ons, seasonal grass growth and wet
weather. A high output current, typically over 40 Amps indicates there is a very high
load or short circuit on the fence.
Voltage Display
Output voltage is an indica on of how eff ec ve the shock is on your fence. It is
generally recommended to have 3KV or above on the fence at any me. If the output
voltage is too low there will not be enough voltage to ‘break’ through the animals
hide and deliver an eff ec ve shock.
Zone Indicators
The zone indicators show what zones are ac ve on the fence system. The Energizer
zone ( ) and Earth zone ( ) are always available. Zones 1 – 6 can be added by
installing a combina on of up to 6 Fence Monitors or Alarm Systems. See
Op onal
Accessories
(p.19)
Naviga on Bu ons
The naviga on bu ons allow you to view the performance of diff erent areas of your
fence system. By pressing (
<
) or (
>
) you can scroll through the zone indicators to
view fence or earth voltage. The zone you are looking at is highlighted by the zone
indica on arrow (
).
Standby Bu on
Pressing the standby bu on turns the energizer pulses on or off .
Se ngs Bu ons
The se ngs bu ons allow you to adjust the alarm levels and output voltage of the
energizer. Pressing the setup bu on (
) turns off the energizer pulses and enters
setup mode. If no further bu ons are pressed within 10 seconds the energizer
automa cally exits setup mode and starts pulsing as normal.
Other Icons
The controller may occasionally display other icons for your informa on.
Energizer over-temperature. The energizer has detected that its internal
temperature is too high to operate safely, has automa cally slowed its pulse
rate down and may shut down un l the temperature has decreased.
Se ngs mode. The user has entered the controller setup mode.
Standby mode. The energizer has been placed into standby and has stopped
pulsing. Press the standby bu on to resume normal opera on.