DairyScale
Installer
manual
3E0673
Page
34
Power
Suppply
Cable
specification
In
order
to
correctly
determine
the
cable
requirements,
use
the
following
procedure.
Output
Voltage
12
V
Current
4
Amps
Max
voltage
drop
0.5
V
Minimum
cable
resistance
0.125
Ohms
Procedure
To
calculate
the
required
cable
resistance
per
metre
use
the
following:
1.
Determine
the
exact
distance
from
the
Power
supply
to
the
Scale
in
metres.
2.
Determine
the
allowable
resistance
per
metre
using
the
following
equation:
Resistance
per
metre
=
0.125
ohms
Distance
from
Power
Supply
to
Scale
in
metres
3.
Take
the
following
information
to
your
cable
supplier
and
get
a
cable
that
meets
the
requirements.
Distance
from
the
Power
supply
to
the
Scale
in
metres,
and
Resistance
per
metre
as
per
the
previous
calculation.
Note:
The
cable
used
must
have
a
resistance
per
metre
of
less
than
the
calculated
value.
Scale
power
requirements
Voltage
12
V
Approximate
consumption
(without
platform
set)
65
mA
Approximate
consumption
(with
platform
set)
115
mA