Cardax IV Reader connection:

Positive

Red

Negative

Black

HBUS Termination Orange
HBUS A

Green

HBUS B

Brown

CDXIV TX

White

CDXIV RX

Blue

Car

da

x IV R

eader

5. 

Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding 

the top, press the bottom of the facia assembly down into the bezel.

6. 

Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the 

hole at the bottom of the bezel to secure the facia assembly.  

Note: 

 The Torx Post Security screw needs only to be lightly tightened.

Bezel

Fit screw to secure facia to bezel

Connection

Reader tail

Building cable

Facia

7. 

Removal of the facia assembly is a simple reversal of these steps.

8. 

Configure the reader in Command Centre.  If the reader is connected as an HBUS Reader, refer to 

the topic 

"Configuring HBUS Devices"

 in the Command Centre Configuration Client Online Help.  

If the reader is connected as a Cardax IV Reader, refer to the topic 

"Creating Readers"

 in the 

Command Centre Configuration Client Online Help.

Summary of Contents for C300420

Page 1: ...r Edition 1 August 2016 Copyright Gallagher Group Limited Gallagher T12 Reader Installation Note T12 Mifare Reader Black C300420 T12 Mifare Reader White C300421 T12 Multi Tech Reader Black C300440 T12...

Page 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Page 3: ...016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 4 3 Distance between readers 7 4 Installation 7 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8...

Page 4: ...th the Gallagher Controller IMPORTANT HBUS compatibility HBUS communications are supported with sites running Gallagher Command Centre vEL7 00 software or later IMPORTANT Multi Tech readers Using dual...

Page 5: ...ments must be considered Although the reader is specified to operate at 9 Vdc for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc HBUS cabling t...

Page 6: ...e HBUS Device Cable distance Cable type Cable format HBUS single reader connected using data only in a single cable Cardax IV single reader connected using data only in a single cable HBUS Cardax IV s...

Page 7: ...This equipment contains components that can be damaged by electrostatic discharge Ensure both you and the equipment are earthed before beginning any servicing The Gallagher T12 Reader is designed to...

Page 8: ...le Connect the wires for the appropriate reader you wish to interface either an HBUS Reader or a Cardax IV Reader as shown in the following diagrams Note Mobile credential readers must be connected as...

Page 9: ...g a T10 Torx Post Security screwdriver through the hole at the bottom of the bezel to secure the facia assembly Note The Torx Post Security screw needs only to be lightly tightened Bezel Fit screw to...

Page 10: ...been granted Flashes Red Access has been denied Flashes Blue Reading a Gallagher mobile credential LED squiggle Cardax IV indication 3 Flash Amber No communications with the Controller On Green or Re...

Page 11: ...70 C Note Direct sunlight may increase the internal reader temperature above the ambient temperature level Humidity 0 95 non condensing3 Environmental protection IP68 Impact rating IK07 Unit dimensio...

Page 12: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Page 13: ...t Gallagher Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 35 mm 1 38 26 mm 1 29 mm 1 14 86 mm 3 39 13 mm 1 2 diameter hole for cabl...

Reviews: