background image

Page  2   

3E4289 Gallagher T11 Reader | Edition 1 | August 2016

 

Copyright © Gallagher Group Limited

Disclaimer

This document gives certain information about products and/or services provided by Gallagher Group Limited 

or its related companies (referred to as "Gallagher Group").

The in

formation is indicative only and is subject to change without notice meaning it may be out of date at any 

given time.  Although every commercially reasonable effort has been taken to ensure the quality and accuracy 

of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should 

not be relied on as such.  To the extent permitted by law, all express or implied, or other representations or 

warranties in relation to the information are expressly excluded. 

Neither Gallagher Group nor any of its directors, employees or other representatives shall be responsible 

for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the 

information provided.

Except where stated otherwise, the information is subject to copyright owned by Gallagher Group and you may 

not sell it without permission.  Gallagher Group is the owner of all trademarks reproduced in this information.  

All trademarks which are not the property of Gallagher Group, are acknowledged.

Copyright © Gallagher Group Ltd 2016.  All rights reserved.

Summary of Contents for C300410

Page 1: ...11 Reader Installation Note T11 Mifare Reader Black C300410 T11 Mifare Reader White C300411 T11 Multi Tech Reader Black C300430 T11 Multi Tech Reader White C300431 T11 PIV Reader Black C305410 T11 PIV...

Page 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Page 3: ...016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 5 3 Distance between readers 7 4 Installation 8 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8...

Page 4: ...IV Reader An HBUS Reader uses the HBUS communications protocol to communicate with the Gallagher Controller A Cardax IV Reader uses the Cardax IV Reader communications protocol to communicate with the...

Page 5: ...lagher T11 Reader requires a minimum cable size of 4 core 24 AWG 0 2 mm2 stranded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a single cable to carry...

Page 6: ...evice HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termination jumper RS485 1 T or Star circuits are not permitted between HBUS devices HBUS Device Termina...

Page 7: ...es to equivalent wire gauges are only approximate Recommended cable types for optimal HBUS RS485 performance Not applicable for PIV or Gallagher mobile credential reader installations Notes Shielded c...

Page 8: ...not mounting to a flush box use the reader bezel as a guide to drill all five holes Drill the 13 mm 1 2 inch diameter centre hole this is the centre hole for which the building cable will exit the mou...

Page 9: ...lack HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue HBUS Reader Positive Red Negative Black HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Bl...

Page 10: ...der is not assigned to a door or elevator car On Green or Red Fully configured and functioning normally Green Access mode is Free Red Access mode is Secure Flashes Green Access has been granted Flashe...

Page 11: ...70 C Note Direct sunlight may increase the internal reader temperature above the ambient temperature level Humidity 0 95 non condensing3 Environmental protection IP68 Impact rating IK07 Unit dimensio...

Page 12: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Page 13: ...her Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 40 mm 1 57 32 mm 1 26 48 mm 1 89 115 mm 4 53 13 mm 1 2 diameter hole for cable 70...

Reviews: