background image

Page  12   

3E4289 Gallagher T11 Reader | Edition 1 | August 2016

 

Copyright © Gallagher Group Limited

Approvals and standards

This symbol on the product or its packaging indicates that this product must not be disposed 
of with other waste.  Instead, it is your responsibility to dispose of your waste equipment by 
handing it over to a designated collection point for the recycling of waste electrical and electronic 
equipment.  The separate collection and recycling of your waste equipment at the time of disposal 
will help conserve natural resources and ensure that it is recycled in a manner that protects human 
health and the environment.  For more information about where you can drop off your waste 
equipment for recycling, please contact your local city recycling office or the dealer from whom 
you purchased the product.

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.

Note:

  Changes or modifications not expressly approved by Gallagher Limited could void the user's 

authority to operate this equipment.

Note:  

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation.  This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications.  However, there is no 
guarantee that interference will not occur in a particular installation.  If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures:

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry 

Canada

This device complies with Industry Canada licence-exempt RSS standard(s).  Operation is subject to 
the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device.

Industrie 

Canada

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 
exempts de licence.  L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil 
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage 
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

ETSI EN 300 330-2 V1.5.1:2011

 

EN50130-4:2011

 

  

     

    

     

Please refer to the document 

“3E2793 Gallagher Command Centre UL Configuration Requirements”

 for a guide 

to configuring the Gallagher system to the appropriate UL Standard.

US - Equipment: com, burg and acc reader

 

CA - Equipment: com, burg reader

Summary of Contents for C300410

Page 1: ...11 Reader Installation Note T11 Mifare Reader Black C300410 T11 Mifare Reader White C300411 T11 Multi Tech Reader Black C300430 T11 Multi Tech Reader White C300431 T11 PIV Reader Black C305410 T11 PIV...

Page 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Page 3: ...016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 5 3 Distance between readers 7 4 Installation 8 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8...

Page 4: ...IV Reader An HBUS Reader uses the HBUS communications protocol to communicate with the Gallagher Controller A Cardax IV Reader uses the Cardax IV Reader communications protocol to communicate with the...

Page 5: ...lagher T11 Reader requires a minimum cable size of 4 core 24 AWG 0 2 mm2 stranded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a single cable to carry...

Page 6: ...evice HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termination jumper RS485 1 T or Star circuits are not permitted between HBUS devices HBUS Device Termina...

Page 7: ...es to equivalent wire gauges are only approximate Recommended cable types for optimal HBUS RS485 performance Not applicable for PIV or Gallagher mobile credential reader installations Notes Shielded c...

Page 8: ...not mounting to a flush box use the reader bezel as a guide to drill all five holes Drill the 13 mm 1 2 inch diameter centre hole this is the centre hole for which the building cable will exit the mou...

Page 9: ...lack HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue HBUS Reader Positive Red Negative Black HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Bl...

Page 10: ...der is not assigned to a door or elevator car On Green or Red Fully configured and functioning normally Green Access mode is Free Red Access mode is Secure Flashes Green Access has been granted Flashe...

Page 11: ...70 C Note Direct sunlight may increase the internal reader temperature above the ambient temperature level Humidity 0 95 non condensing3 Environmental protection IP68 Impact rating IK07 Unit dimensio...

Page 12: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Page 13: ...her Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 40 mm 1 57 32 mm 1 26 48 mm 1 89 115 mm 4 53 13 mm 1 2 diameter hole for cable 70...