6
English
Step 3 -
Connect the fence
Connect energizer’s red terminal to the fence using Lead-
out Cable G6270: remove 5cm (2”) of plastic coating from
one end of the cable and attach to the red terminal on
the energizer. Attach the other end of the cable to the
fence using a Joint Clamp G6030.
Red
Green
To earth system
To fence
Lights
long galvanised stakes G8790
or Super Earth Kits G8800,
3m (10ft) apart, connected
to the energizer by high
quality Lead-out cable
G6270. Do not use materials
that rust.
(Use G6272 if the earth
system is over 100m (300ft)
from the energizer).
Find a location for your earth
system that is permanently
damp, has high fertility or
salinity and is away from
dairy sheds. Install the earth
system at least 10m (33ft)
from any power supply earth
peg, underground telephone
or power cable. The best
construction is 2m (61/2ft)
Handy
hint
G8790
G8760
Step 4 -
Turn on the energizer
Plug the energizer into a power outlet and check that the
lights on the front of the energizer are fl ashing.
The green (ENERGIZER) indicator light fl ashes when the
energizer is working correctly.
The red (FENCE) indicator light fl ashes with each fence pulse,
if the voltage is over 4000 volts (approx.) to indicate fence
condition. If the fence is overloaded the indicator will either
fl ash intermittently or not at all.