5.0 MAINTENANCE

 

 

5.1  General 

 

A.  Other than periodical dusting, and wipe down, the OPTI-LITE and Light Guide 

requires no other maintenance. 

 

B.  When cleaning is needed, use a commercial glass cleaner or common 

household detergent to gently wipe down the exterior of the Illuminator Box 

and Light Guide. 

 

CAUTION! 

Always unplug the power cord before performing any cleaning or servicing. Do 

not use excess water, treated cloth, harsh cleaning agents or sprays. Use any 

cleaning fluid sparingly. If moisture is present in the interior, allow the unit to 

dry thoroughly before use. 

 

C.  Occasionally dust should be removed from the Illuminator Box by using 

vacuum or commercial can of compressed air. Pay special attention to the fan 

blades  at the rear of t unit and the air vents in the front (around the 

Nosepiece) and on the bottom of the Main Housing. 

 

5.2  Lamp Replacement  

 

A.  Ensure the ON/OFF Intensity Knob is in the OFF position. Unplug the power 

from the wall. 

 

WARNING! 

Always allow the Unit time to cool before attempting to replace a broken Lamp. 

Surfaces may remain hot for a time, possibly causing a burn if touched. 

 

B.  Turn the Cover Lock Knob (on the bottom of the Illuminator Box) counter-

clockwise until the Lamp Access Panel opens. Gently pull the Lamp away from 

the Main Housing. 

 

C.  Insert new Lamp into the Lamp Holder ensuring a snug fit. Reconnect the Lamp 

Socket and close the Panel. 

 

 

 

Summary of Contents for OPTI-LITE

Page 1: ...ER OPTIC LIGHT GUIDE INSTRUCTION MANUAL MANUAL NUMBER 21 11 1180 Revision A Issued July 2013 Revised March 2022 Copyright 2013 Galiso Inc 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 854 3789 ww...

Page 2: ...LITE Operations 4 1 4 1 Operation 4 1 4 2 Intensity 4 1 5 0 Maintenance 5 1 5 1 General 5 1 5 2 Lamp Replacement 5 1 5 3 Fuse Replacement 5 1 5 4 Nosepiece Adapter Insert 5 2 5 5 Troubleshooting 5 3...

Page 3: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Page 4: ...The light source is CSA listed to UL 1571 120 V version The updated OPTI LITE features an ergonomic Handle a Nosepiece Adapter with locking design to keep Light Guides steady and Intensity Control fro...

Page 5: ...i Lite Kit Note Light Guide Receptacle showing without adapter Illuminator Box Overall Height 4 9 125 mm Overall Width 8 205 mm Overall Depth 7 180 mm Unit Weight 9 9 lbs 4 5 kg including cord Light G...

Page 6: ...lace the device next to other sensitive electronic devices Failure to do so could result in errant operation of the nearby device D Avoid using or storing the OPTI LITE in or on areas of excessive vib...

Page 7: ...f power the OPTI LITE will remain off when power is restored to the unit When power is returned turn the Intensity Knob to OFF and then slowly turn up intensity until light is returned L Do not defeat...

Page 8: ...e 3 1 Minimum Clearance B Ensure the Lamp has not been dislodged from the Lamp Holder during shipment by opening up the Lamp Replacement Door and visually inspecting the Lamp The Lamp should fit symme...

Page 9: ...Section 3 2 21 11 1180 This page intentionally left blank...

Page 10: ...ol down time of one to two minutes before turning the unit off C After the above steps have been performed the Light Guide can be inserted into the cylinder neck to proceed with inspections Always avo...

Page 11: ...Section 4 2 21 11 1180 This page intentionally left blank...

Page 12: ...nally dust should be removed from the Illuminator Box by using vacuum or commercial can of compressed air Pay special attention to the fan blades at the rear of t unit and the air vents in the front a...

Page 13: ...mic Lamp Socket See Figure 5 1 Lamp Replacement Note Remember to never touch the Bulb or the Reflector in the Lamp Only touch the sides when inserting a new Lamp E Insert a new Lamp into the Lamp Brac...

Page 14: ...B To install the new Nosepiece Adapter unscrew all three Thumb Screws Turn the Illuminator Box over to allow the Adapter to fall out Insert the new Nosepiece Adapter and re tighten the Thumb Screws 5...

Page 15: ...800 854 3789 to receive a return authorization number and shipping instructions G The Light is off Fan does not operate 1 Make sure the power cord is inserted completely into the IEC connector and als...

Page 16: ...x 20 L 3 85 11 0043 Light Guide 1 4 x 5 ULG 4 85 11 0050 Light Guide 1 4 x 6 L 5 85 11 0061 Light Guide 1 8 x 5 L 6 85 11 0062 Light Guide 1 8 x 10 L 7 85 11 0063 Light Guide 1 4 x 5 L 8 85 11 0064 L...

Page 17: ...Section 5 6 21 11 1180 This page intentionally left blank...

Page 18: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...

Reviews: