5.0 OPERATION

 

 

A.  Check that Cylinders are emptied and drained of water. 

 

B.  Place a Probe into each Cylinder that is going to be dried, and align under each 

individual Manifold Outlet. Connect each Probe by pushing up into a Quick 
Connect on the Upper Body. 

 

NOTE: 

Avoid bending or otherwise damaging the Probes.

 

 

C.  When cylinders have been loaded, flip the Power Switch up, to the ON position. 

 

D.  The display on the PID Controller will read the last set temperature. For example, 

see Figure 2, below. The temperature to achieve (Goal Temperature), shown 
here is 250° F. Each time the HDD is powered up, the display will read the 
temperature that was set to achieve when the machine was turned off. 

 

Figure 2, HDD Controller 

 

E.  The Current Running Temperature of Air Flow, as measured in the Main Body 

Heat Tube. Shown here as 242°F. This will be an approximate of the temperature 
of air flow through the Probes. 

 

F.  To change the desired temperature, simply press the Arrow Up 

 or Arrow 

Down 

Buttons. Increments will change by 1°F by pressing once. By pressing 

and holding the Up or Down Buttons, increments will begin changing by 10° F. 

 

Summary of Contents for HDD-8RB

Page 1: ...ntrol GALISO CYLINDER DRYER INSTALLATION OPERATION INSTRUCTION MANUAL MANUAL NUMBER 21 11 1025 Issued November 2016 Rev A Copyright 2016 Galiso Inc 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 8...

Page 2: ...roduction 1 1 2 0 Specifications 2 1 3 0 Safety 3 1 4 0 Installation 4 1 5 0 Operation 5 1 6 0 Maintenance 5 2 List of Tables and Figures Number Title Page Figure 1 HDD Galiso Cylinder Dryer 2 1 Figur...

Page 3: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Page 4: ...um cylinders To speed the process of loading and unloading Cylinders the Dryer Probes have a Quick Connect ends that allow easy attachment to the machine For convenience a platform and a 110 Volt Elec...

Page 5: ...on M anual HDD 8RB CAUTION HOT SURFACES Blower Motor Front Legs Rear Leg Dryer Probes x 8 Control Box Figure 1 HDD Galiso Heavy Duty Dryer Power Requirements 220 Volt single phase 50 60 Hz 220 Volt t...

Page 6: ...chance of operator injury due to slips or falls B Always wear gloves eye protection and foot protection while operating the HDD C The HDD dryer is capable of producing considerable heat Use insulatin...

Page 7: ...s into the Upper Body Lower the Unit to the floor D Bolt the Blower Motor Assembly to the Leg Brackets E Connect the Flexible Hose from the Blower Motor to the grey plastic Adapter on the Upper Body F...

Page 8: ...et temperature For example see Figure 2 below The temperature to achieve Goal Temperature shown here is 250 F Each time the HDD is powered up the display will read the temperature that was set to achi...

Page 9: ...For any problems or programming questions please contact Galiso Inc At 1 800 854 3789 K After cylinders have been drying for a short time 5 10 minutes check each cylinder for dryness and replace on th...

Page 10: ...21 11 1025 Wiring A Blower Motor Ground Wire T1 Brown T2 Black T3 Orange Blower Motor to T1 T2 T3...

Page 11: ...Wiring B 21 11 1025 Ground Wire L1 L2 L3...

Page 12: ...21 11 1025 Schematic...

Page 13: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...

Page 14: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...

Reviews: