26
01.02.2021
Cod. 80007060a - GB
8. Dixell XR77CX control panel
Attention:
The cabinet is equipped with a
digital thermometer
positioned inside the display area, usually close
to the front glass.
The displayed temperature corresponds to the temperature in the refrigerated cabinet; there-
fore refer to this value for preserving the goods properly.
The temperature displayed by the controller corre-
sponds to the set point value. For technical reasons, the temperature values provided by the two displays (i.e. ther-
mometer in the refrigerated cabinet and controller display), even if related to one another, could be different and vary
during the cabinet’s operation. This fact is not an anomaly or a technical fault. To modify the working temperature, it is
necessary to consider the temperature displayed by the digital thermometer
inside the refrigerated cabinet
, and
then increase/decrease to the set point value memorized by the controller.
8.4 User interface
1
2
3
4
5
6
Pos.
Keys
2
/
3
SET
4
5
6
1
AUX
Function
To switch on and off the lighting (if any)
To start manual defrost
To display or modify the set point
UP arrow
—
to increase the set point value
DOWN arrow
—
to decrease the set point value
Stand
-
by of the cabinet (function disabled)
LED
MODE
Flashing
ON
Flashing
ON
ON
ON
Function
Compressor enabled
Compressor in waiting mode (delayed start)
Defrost in progress
Dripping phase in progress
Temperature alarm
Continuous cycle running
°C
ON
Measurement unit of temperature
°C
Flashing
Programming phase (for maintenance technicians only)