background image

 

Operation Manual 

(GS-105HS) 

 

Safety Instructions 

 

 

When using your heat press, 

basic precautions should be followed, 

including the following: 

 

 

1.  Read all instructions. 

2.  Use heat press only for its intended use. 

3.  To reduce the risk of electric shock, do not immerse the heat press in water or 

other liquids. 

4.  Never pull power cord to disconnect from outlet, instead grasp plug and pull to 

disconnect. 

5.  Do not allow power cord to touch hot surfaces, allow heat press to cool completely 

before storing. 

6.  Do not operate heat press with a damaged cord or if the equipment has been 

dropped or damaged. To reduce the risk of electric shock, do not disassemble or 

attempt to repair the heat press. Take it to a qualified service person for 

examination and repair. Incorrect assembly or repair could increase the risk of fire, 

electric shock, or injury to persons when the equipment is used. 

7.  This appliance is not intended to be used by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

8.  Close supervision is necessary for any heat press being used which can be sure 

to keep children away from the equipment. Do not leave equipment unattended 

while connected. 

9.  Burns can occur when touching hot metal parts. 

10. To reduce the likelihood of circuit overload, do not operate other high voltage 

equipment on the same circuit. 

11. If an extension cord is necessary, then a 20-amp rated cord should be used. 

Cords rated for less amperage may overheat. To arrange the cord in a correct way 

so that it cannot be pulled or tripped over. 

 

 

 

 

 

Summary of Contents for GS-105HS

Page 1: ...orrect assembly or repair could increase the risk of fire electric shock or injury to persons when the equipment is used 7 This appliance is not intended to be used by persons including children with...

Page 2: ...mble the Control Box 6 Connecting the System 7 Ramspin system Auto Manual switch 7 Turning the System On 8 Adjusting the Temperature 8 Adjusting the Time 8 Adjusting the Pressure 9 Printing and Pressi...

Page 3: ...ower Platen Yes Power 110volt 1800W 16 4Amps Temperature Range Max 430 221 Heating Up Time 180 20 minutes Time Range 0 999S Platen Exchange System Ramlock quick change system Optional Lower Platens So...

Page 4: ...4...

Page 5: ...5 Control Panel Guide Operation Instructions...

Page 6: ...machine in the right position figure 1 1 1 2 Fasten the control box onto the machine with 4 screws tightly figure 1 2 1 3 Connect 5 phase aviation plug and 2 phase aviation plugs then fasten tightly f...

Page 7: ...ces especially more than one heat seal machine plugged in should not be used NOTE If the supply cord is damaged be sure to contact the manufacturer its service agent or a similar qualified person for...

Page 8: ...e 4 ADJUST THE TEMPERATURE 4 1 Press SET button Set Temp lights located in the display will illuminate figure 4 1 4 2 Next press the UP and DOWN Arrow to increase or decrease the figure to set the Tem...

Page 9: ...2 Next press UP and DOWN Arrow to increase or decrease the figure to set the Time The time setting range is from 0 to 999S 6 1 Once you have adjusted the time press SET button again Counter lights lo...

Page 10: ...wise to decrease the Pressure The readout will display the Pressure when locked down in the print position 7 3 A visual Pressure Readout is located on the lower right side of the LCD Display When the...

Page 11: ...nds Calibrate lights located in the display will illuminate indicating you are in the adjust temperature calibration mode fig 10 1 9 1 Press the UP Arrow and SET button together and hold for 3 seconds...

Page 12: ...446 1 3 Circuit breaker 18A 1800349 1 4 On off switch 1800346 1 5 Emergency stop button 1200579 1 6 socket 1800344 1 7 Triac 1800586 1 10 Cooing sheet 1300672 1 11 Terminal Block 1800345 1 12 Circuit...

Page 13: ...0155 1 36 Screw M8 16 1901071 1 37 Adjustment spindle base 1800142 1 39 Adjustment spindle 1800087 1 40 Thermocouple 1800281 1 42 Balance screw 1901074 1 43 Thermostat 1800133 1 44 Lower platen 180038...

Page 14: ...art Name Part No Qty 1 Cooper bush 1200075 4 3 Sliding Lower Platen Base 1200426 1 4 Supporting Block 1200052 1 4 Bearing block 1200648 4 5 Plated bar fixed board 1200044 2 6 Plated bar 1701037 2 7 O...

Page 15: ...amlock locking screw 1900959 1 5 Ramlock handle 1200956 1 6 Ramlock locking set female 1200957 1 Optional Platens Sold Separately Part Name SKU Size LTPPLATENSETRAM 0404 4in x 4in LTPPLATENSETRAM 0610...

Page 16: ...16 Electrical Schematic...