background image

12 

G8-09-11-2018 

Galaxy Unlimited, LLC Remote Control Box Warranty

 

This warranty is for the electrical components of the Remote Control Box 

which begins on the day of purchase from Galaxy Unlimited, LLC for a 

period of 1 year thereafter. During this period, Galaxy Unlimited, LLC will 

replace electrical components, without charge, for the components of 

the Remote Control Box, or any part or piece thereof, which exhibits a 

manufacturing defect or defect in craftsmanship. Defect is determined at 

the absolute and sole discretion of Galaxy Unlimited, LLC.  

 

To submit an acceptable claim under this limited warranty, the Original 

Purchaser must provide the following information in writing to:  

 

Galaxy Unlimited, LLC  

6470 State Highway 198 

Mabank, TX 75156  

 

 

Full Name and Address  

 

Serial Number of Unit  

 

Clear and specific description of the defect  

 

Ship malfunctioning Remote Control Box to above address for 

confirmation/evaluation at the expense of the customer.  

 

This limited warranty is valid only when such products are used under 

normal conditions of recommended use. This limited warranty does not 

cover replacement or repair of any part there of damaged by acts of God, 

abuse, accident, misuse, neglect, alteration, repair, disaster, overloading, 

negligence, unauthorized use, improper installation, improper testing, 

improper product selection, failure to follow maintenance 

recommendations, failure to follow instructions or warnings, or any other 

case beyond the control of Galaxy Unlimited, LLC.  

 

All warranties implied by law, including implied warranties of 

merchantability and fitness for a purpose, are disclaimed or, if a 

disclaimer is not permitted by applicable state law, are expressly 

limited to the durations of the coverage period set forth above.

 

Summary of Contents for Gel Pad

Page 1: ...G8 2 23 1 Control Box Wiring Programming Guide...

Page 2: ...r for your lift Here you can turn your unit off and on send the unit to its levels or stop travel in any direction The remotes are also programmed from the Gel Pad On 2 stop lifts or lifts for marine...

Page 3: ...during this process Please read through instructions thoroughly before starting The control board will exit the programming mode after 7 seconds of inactivity you may have to practice the steps a few...

Page 4: ...the green LED beside the button lights up approximately 3 seconds 3 Press either the up or down button on your remote you will see a corresponding flash from the learn LED o Additional Remotes Repeat...

Page 5: ...trician or contact our office Galaxy Unlimited LLC is not responsible for incorrect field wiring damages to equipment or harm to anyone or anything Incorrect field wiring will void warranty Motor Wiri...

Page 6: ...r contact our office Galaxy Unlimited LLC is not responsible for incorrect field wiring damages to equipment or harm to anyone or anything Incorrect field wiring will void warranty Motor Wiring Black...

Page 7: ...s to your limit switch cord color to color The necessary blue wire nuts will be in the bag with the control box mounting hardware a Red Limit for the top stop When disconnected from the black wire the...

Page 8: ...op and bottom limits will hit on opposite sides of their microswitches based on cam rotation d 1 8th turn on the adjustment screw is about 6 8 inches of travel e On each test of adjustment run the lif...

Page 9: ...a cam per interlock is used aside from special cases Typically a white wire for the first interlock if 3 stop red with black stripe then blue if there is a second interlock if 3 stop red with black st...

Page 10: ...ed Downstairs application Black Not Used White Not Used 5 Route all wires and tuck the circuit board back in its place 6 Reinstall Gel Pad Route the ribbon cable so that it does not kink sharply 7 Rec...

Page 11: ...cker approximately 6 from the edge of the unit on the subfloor beams Then you will drill an 11 16 hole in the beam and install the cable gland as shown Next route travel wire from the switches through...

Page 12: ...Serial Number of Unit Clear and specific description of the defect Ship malfunctioning Remote Control Box to above address for confirmation evaluation at the expense of the customer This limited warra...

Reviews: