background image

 

Magnetic Limit Switch Set up 

The Galaxy Cargo Lift includes Magnetic Limit Switches, wiring and the necessary mounting hardware. A three-stop 
cargo lift will have three magnetic limit switch bags. Each bag contains one Wired and one Non-wired component. The 
two Components comprise one Magnetic Limit Switch. 

The magnetic limit switch is designed to stop the lift at a specific location when the two components are near one 
another. There are no mechanical components, so once the magnetic limit switch is firmly attached in the desired 
position there should be only minor adjustments required in the future. 

The installation hardware includes six (6) pieces of two-sided tape. The tape should be used to temporarily attach the 
Wired and Non-Wired Components to the cargo lift. This will allow the two Components to be easily removed and 
relocated during the installation process before permanently attaching the Components with screws. 

Please Read All Instructions carefully before starting the installation of the cargo lift. 

Limit Switch Installation Procedure 

1.

 

Before installing the cargo lift basket to the vertical beams, use the two-sided tape to temporarily mount the 
Non-wired Component of the Magnetic Limit Switch on the outside of one of the external backbones of the 
cargo lift. Either of the two backbones is acceptable but note that the Wired Component of the Magnetic Limit 
Switch will need to be mounted on the vertical beam corresponding to that backbone and you should consider 
how the wire will be run from the vertical beam to the control box

. The Non-Wired component of the Magnetic 

Limit Switch must be located within ½ inch of the furthest point to the back of the lift.

 That is extremely 

important as it allows for a precise proximity point between the two components (wired and non-wired) of the 
magnetic limit switch 

.  

2.

 

Mount the cargo lift basket to the vertical beams and complete the installation of the head assembly, motor and 
control box. 

3.

 

With the basket installation complete, lower the basket to the desired bottom position. Apply the two-sided 
tape to the back of the mounting bracket (see figure 12), position the mounting bracket to the back of the 
vertical beam (see figure 13), attach the Wired Component of the Magnetic Limit Switch to the bracket using the 
included screws (see figure 14). The Wired Component should be located perpendicular to the Non-Wired 

Figure 10. Two-sided tape attached to 

magnetic component 

Figure 11. Magnetic component 

attached to the backbone 

Summary of Contents for 1M3S

Page 1: ...1M3S Control Box Wiring Programming Guide...

Page 2: ...ote s Figure 3 Control Board Figure 8 Magnetic Limit Switch Wired Portion Figure 7 Magnetic Limit Switch Non Wired Portion Figure 6 Magnetic Limit Switch Mounting Bracket Figure 2 Call Send Box Figure...

Page 3: ...nctions The Gel Pad is the primary control center for your lift The Gel Pad can turn your unit off and on send the unit to its levels or stop the travel in any direction The remotes are programmed fro...

Page 4: ...ess the up button on each remote once you will see a corresponding flash from the learn LED 4 Give the learn mode 10 seconds to expire you will see a rapid flash from the learn LED 5 Now test the remo...

Page 5: ......

Page 6: ...240 Volt standard Lift Wiring CB...

Page 7: ...e indicated in the Control box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 Orange T4 Red T5 Join T2 T3 T8 Inside Control...

Page 8: ...120 Volt Standard Lift Wiring CB...

Page 9: ...rol box door please call our technical support team to receive further instructions Phone 888 317 7203 Inside Motor Wiring Black T1 T3 Orange T2 T4 Red T5 White T8 Inside Control Box Motor Wiring Oran...

Page 10: ...240V or 120V Overlimit Set Up 1 Connect the black wire from the Overlimit cable to the black wire coming from the 9 Pin Molex connecter 2 Connect the white wire from the Overlimit cable to the black...

Page 11: ......

Page 12: ...temporarily mount the Non wired Component of the Magnetic Limit Switch on the outside of one of the external backbones of the cargo lift Either of the two backbones is acceptable but note that the Wi...

Page 13: ...ence figure 16 below shows the Control Board CB outside the control box Figure 15 shows CB installed inside the control box There are 5 wires Green Blue White Red and Black coming from the middle edge...

Page 14: ...CB Limits...

Page 15: ...nnect the green limit wire from the CB to the red wire for the Bottom Mag Note the black wire for the Magnetic Limit Switch is not used 11 Use wire nuts to secure the connections 12 Carefully replace...

Page 16: ...Additional Equipment Setup Section Not Standard Call Send Station Call Send...

Page 17: ...ol box while attaching the wires 3 Find the blue screw terminals located near the Gel Pad connector as shown in figure 18 below 4 Connect the wires from the call send station as shown in the figure 18...

Page 18: ...tion Not Standard Pan Switch 1 Connect the black wire from the Pan Switch to the green limit wire coming off the CB 2 Connect the white wire from the Pan Switch to the red wire coming off the bottom m...

Page 19: ...el cable through the gland and start making the necessary connections at the bottom of the basket a Black wire from travel cable to the White wire from Rocker Switch 1 See Diagram Below then connect t...

Page 20: ......

Page 21: ...ar and specific description of the defect Ship malfunctioning Remote Control Box to above address for confirmation evaluation at the expense of the customer Must register Control Box online This limit...