GALA CUT 350 K G.E.
Pág. 17
4. MAINTENANCE OPERATIONS. RECOMMENDATIONS.
GOOD MAINTENANCE OF THE EQUIPMENT WILL PREVENT A LARGE PERCENTAGE OF FAULTS.
Before carrying out any operations on the machine place the general switch to “0” position and disconnect the
machine from the mains
Any interventions to the machine to carry out maintenance and repair operations must be performed by
authorised personnel. The recommended frequencies presuppose frequent use of the machine.
VERIFICATION FREQUENCY
ACTION
IN EACH USE
Verify the state and appropriateness of the accessories for the
work to be carried out.
The torch has a safety switch. Verify that indicator 6 never lights
up when the nozzle-support has been removed, after pressing
the torch.
WEEKLY
The machine ventilations must be kept free. The machine must
be placed in a location where there is air renewal.
Verify that the power supply and torch hose insulations have not
suffered damage. The cutting process gives off materials at
high temperatures that may harm them.
Blow the inside of the machine with compressed air
3 MONTHS
Cleaning air filters
WARNING! SUFFICIENTLY SEPARATE THE MACHINE FROM THE WORKSTATION.
PREVENT METAL DUST ENTERING THE EQUIPMENT.
F