background image

 

D-12 A, D-20 A, D-20 AR. Instructions Manual.

 

16 

 

CHAPTER 6. SAFETY MEASURES. 

 

 
  

The use of this equipment requires a maximum amount of responsibility with respect to their use and 

maintenance. Read this safety chapter carefully as well as the rest of the instructions manual. The correct use 
of the equipment will depend on this. 
 
 
 

 

 

 

 

 

 

For your safety and that of others, remember that: 

ANY PRECAUTION MAY BE INSUFFICIENT! 

  

The welding equipment referred to in this manual are electrical. It is 

important therefore to observe the following safety measures. 

 

Any work on the equipment must only be carried out by specialists. 

 

The equipment must be connected to the earth connection and this must always 
be effective. 

 

The equipment must not be located in a damp place. 

 

Do not use the equipment if the welding or supply cables are damaged. Use 
original spares.  

 

Make sure that the part to be welded makes perfect electrical contact with the equipment earth. 

 

During any maintenance operations or when dismantling any element from the inside of the machine, this 
must be disconnected from the electricity supply. 

 

 Do not touch the equipment switches when carrying out a welding operation. 

 

Never lean directly on the work part. We will always work with protection gloves.  

 

Any work on the welding guns and earth clamps will be done with the equipment disconnected (OFF 
Position (O) on the on/off switch). Do not touch the electrically active parts (electrode-holder clamp, earth 
clamp, etc.) with your bare hand. 

 
 
 

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 
 
 

 
 
 
 
 
 

 

 

 

The part to be worked on should be cleaned from possible grease or 

solvents as these may decompose during the welding process giving off fumes which 
could be very toxic. This can also occur with those materials which have some kind 
of surface coating (zinc-plated, galvanised, etc.). Avoid inhaling the fumes given off 
in the process at all times. Protect yourself from the fumes and metal dust which can 
be given off. Use quality approved anti-fume goggles. Work with this equipment 
must be carried out in places or working posts where there is suitable air renewal. If 
welding processes are carried out in closed places the use of suitable fume 
extractors is recommended. 

 

 

 In welding processes, the electric arc formed gives off infrared and 

ultraviolet type irradiations,  these are harmful for the eyes and skin, so these areas 
must be suitably protected with gloves and suitable clothing. The eyes must be 
protected with goggles with an quality approved protection system with a protection 
index of at least 11.  With electric arc welding machines use protection shield for the 
eyes and face. With electric cutting machine use protection goggles. Always use 
quality approved protection elements. Never use contact lenses. They may adhere to 
the cornea due to the great heat given off during the process. Bear in mind that the 
arc is considered to be dangerous within a 15-metre radius. 

 

  

Cast material projections are given off during the welding process so due 

precautions must be taken. There must be a fire-extinguisher near to the working 
area. Do not keep inflammable material or explosives near to the working post. 
Prevent fire caused by sparks or slag. Use quality approved footwear for this type of 
operations. Use approved acoustic protectors in case of too high noise.  

 

  

Never direct the path of the MIG welding gun towards people. The danger 

exists of activating the system. 

 

  

In environments with a high risk of electrical shock, fire, proximity of 

inflammable products or height, observe relative national and international 
provisions. 
 

Summary of Contents for D-12 A

Page 1: ...000 D 20 AR Ref 622 00 000 E ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL GB THIS EQUIPMENT MUST BE USED BY PROFESSIONALS TO HELP YOU IN YOUR...

Page 2: ...RES Page 16 APPENDICES Page 31 DECLARATION OF CONFORMITY EC MARKING ELECTRICAL DRAWINGS DETAIL DRAWINGS AND REFERENCE LISTS F TABLES DES MATI RES CHAPITRE 1 DESCRIPTION G N RALE CARACT RISTIQUES TECHN...

Page 3: ...30 mm Control de velocidad de hilo y tensi n de soldadura Fuentes de potencia electr nicas Posibilidad de incorporar refrigeraci n Puede incorporarse a cualquier fuente de potencia de la l nea GALA I...

Page 4: ...10 mt Ref 637 81 000 Cable 50 mm2 10 mt Ref 638 81 000 Cable 70 mm2 10 mt Ref 639 81 000 ALARGADERA DE CONEXI N Cable 50 mm2 20 mt Ref 637 82 000 Cable 70 mm2 20 mt Ref 638 82 000 Cable 70 mm2 20 mt...

Page 5: ...ci n de soldeo Modo de trabajo 4T Permite liberar el dedo del pulsador de la antorcha efectuando la operaci n del soldeo Para concluir el proceso de soldadura debe oprimirse de nuevo el pulsador de la...

Page 6: ...actancia elevada El sentido en el desplazamiento de la antorcha y la posici n de la misma afectan a la calidad de la costura soldada En el apartado 3 5 del manual de instrucciones de la fuente de pote...

Page 7: ...roviene de la placa electr nica o bien es un fallo de conexi n el ctrica Compruebe que las bobinas del contactor o y electrov lvula no est n abiertas AL DEJAR DE PULSAR EL GAS DE PROTECCI N SIGUE FLUY...

Page 8: ...islamiento ser de una tensi n de 500 V DC y ser aplicado en los siguientes puntos del circuito Entrada rectificador Tierra Ra 50 Mohms Salida rectificador Tierra Ra 50 Mohms Interruptor I2 Salida rect...

Page 9: ...puede suceder con aquellos materiales que incorporen alg n tipo de tratamiento superficial cincado galvanizado etc Ev tese en todo momento la inhalaci n de los humos desprendidos en el proceso Prot ja...

Page 10: ...ers Wire speed and welding voltage control Electronic power sources Possibility of incorporating an cooling unit It can be incorporated into any power source from the GALA INDUSTRIAL line D 20 AR Open...

Page 11: ...00 Cable 50 mm2 10 mt Ref 638 81 000 Cable 70 mm2 10 mt Ref 639 81 000 EXTENSION CORDS Cable 50 mm2 20 mt Ref 637 82 000 Cable 70 mm2 20 mt Ref 638 82 000 Cable 70 mm2 20 mt Ref 639 82 000 RECOMMENDED...

Page 12: ...rking mode In this mode the finger can be removed from the torch pushbutton when carrying out the welding operation To conclude the welding process the torch pushbutton must be pressed again releasing...

Page 13: ...e wire diameter we must consider a high reactance The direction of the torch movement and the position of the torch affect the quality of the welded seam You can consult a series of recommendations de...

Page 14: ...e Contactor or and solenoid valve It must be established whether the fault comes from the electronic board or if it is an electrical connection fault Check that the contactor coils or and solenoid val...

Page 15: ...device will have 500 V DC and will be applied to the following points of the circuit Intake rectifier Earth Ra 50 Mohms Outlet rectifier Earth Ra 50 Mohms Switch l2 Outlet rectifier Ra 50 Mohms Contro...

Page 16: ...also occur with those materials which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes and m...

Page 17: ...s de 30 mm Contr le de vitesse de fil et tension de soudage Sources de puissance lectroniques Possibilit d int grer le dispositif de r frig ration Il peut tre pos sur n importe quelle source de puissa...

Page 18: ...R f 639 81 000 RALLONGE DE BRANCHEMENT C ble 50 mm2 20 mt R f 637 82 000 C ble 70 mm2 20 mt R f 638 82 000 C ble 70 mm2 20 mt R f 639 82 000 TORCHE DE SOUDAGE RECOMMAND E GM 36 R f 006308 GM 36 R f 0...

Page 19: ...oudage Mode de travail 4T Il permet de lib rer le doigt du bouton de la torche pour effectuer l op ration de soudage Pour finir le proc d de soudage il faut appuyer nouveau sur le bouton de la torche...

Page 20: ...du fil est grand plus il faut penser une r actance lev e Le sens de d placement de la torche et la position de cette derni re ont une influence sur la qualit du travail de soudage Le paragraphe 3 5 du...

Page 21: ...l s agit d un d faut de branchement lectrique V rifier si les bobines du contacteur et ou de l lectrovalve sont ouvertes EN ARR TANT DE PRESSER LE GAZ DE PROTECTION CONTINUE PASSER Il y a des impuret...

Page 22: ...N L appareil de mesure d isolation sera d une tension de 500 V DC et il sera appliqu aux points suivants du circuit Alimentation redresseur Terre Ra 50 Mohms Sortie redresseur Terre Ra 50 Mohms Interr...

Page 23: ...ge d gageant une fum e qui peut tre tr s toxique Ceci peut galement arriver avec le mat riel qui a re u un traitement zingage galvanisation etc viter tout moment l inhalation des fum es de soudage Uti...

Page 24: ...Controlo de velocidade de fio e tens o de soldadura Fontes de pot ncia electr nicas Possibilidade de incorporar refrigera o Pode instalar se com qualquer fonte de pot ncia da linha GALA INDUSTRIAL D...

Page 25: ...5 mm2 10 mt Ref 637 81 000 Cabo 50 mm2 10 mt Ref 638 81 000 Cabo 70 mm2 10 mt Ref 639 81 000 PROLONGAS DE CONEX O Cabo 50 mm2 20 mt Ref 637 82 000 Cabo 70 mm2 20 mt Ref 638 82 000 Cabo 70 mm2 20 mt Re...

Page 26: ...a opera o de soldagem Modo de trabalho 4T Permite liberar o dedo do pulsador da tocha efectuando a opera o da soldagem Para concluir o processo de soldadura deve oprimir se outra vez o pulsador da toc...

Page 27: ...o seja alto devemos pensar numa react ncia elevada O sentido no movimento da tocha e a posi o dele mesmo incidem sobre a qualidade da costura soldada No par grafo 3 5 do manual de instru es da fonte d...

Page 28: ...alha provem da placa electr nica ou uma falha de liga o el ctrica Comprove que as bobinas do contactor ou e electrov lvula n o estejam abertas AO DEIXAR DE PULSAR O G S DE PROTEC O SEGUE FLUINDO Exist...

Page 29: ...NICAS AO MEDIR O ISOLAMENTO O medidor de isolamento ser de uma tens o de 500 V DC e ser aplicado nos seguintes pontos do circuito Entrada rectificador Terra Ra 50 Mohms Sa da rectificador Terra Ra 50...

Page 30: ...o Isto mesmo pode suceder com aqueles materiais que incorporem algum tipo de tratamento superficial zincado galvanizado etc Evite se em todo momento a inala o dos fumos desprendidos no processo Protej...

Page 31: ...ription and reference of it EXAMPLE D 20 A Ref 621 00 000 24V 50 60Hz 1 U CSA 5 3 CONTROL ELECTRONIC CARD Ref 618 16 002 F ANNEXES PLANS LECTRIQUES ET CLAT D CLARATION DE CONFORMIT POUR LE MARQUAGE CE...

Page 32: ...CAL CONSTRUCTIONS FABRICATION ET VENTE D APPAREILS DE SOUDAGE AUTOG NE LECTRIQUE ET CONSTRUCTIONS LECTROM CANIQUES FABRICO E VENDA DE APARELHAGENS DE SOLDADURA AUTOG NEA EL CTRICA E CONSTRU ES ELECTRO...

Reviews: