Cycle double operation mode without initial current:
⑤
Push the torch trigger: arc is ignited and current
rises gradually. The torch trigger can be released at
any time.
⑥
Push the torch trigger and release it at once: current
drops to pilot arc current value.
⑦
Push the torch trigger and release it at once: current
gradually rises again, and then turn to
②
.
⑧
If push the torch trigger twice within 0.5s, the
current will drop gradually, and arc will stop.
Cycle double operation mode with initial current:
⑤
Push the torch trigger: arc is ignited and current
reaches the initial value. The torch trigger can be
released at any time.
⑥
Push the torch trigger and release it at once: current
gradually rises.
⑦
Push the torch trigger and release it at once: current
drops to pilot arc current value, and then turn to
②
.
⑧
If push the torch trigger twice within 0.5s, the
current will drop gradually, and arc will stop.
Single operation 3T mode:
④
Push the torch trigger: arc is ignited and current
rises gradually.
⑤
Release it: current drops to pilot arc current value.
⑥
Push it again: arc stops.
Double operation 3T mode:
④
Push the torch trigger: arc is ignited and current
rises gradually. The torch trigger can be released at
any time.
⑤
Push the torch trigger and release it at once: current
drops to pilot arc current value.
⑥
Push it again: arc stops.
Real time waveform control operation mode with initial
current (intermittent up-down):
⑦
Push the torch trigger: arc is ignited and current
reaches the initial value.
⑧
Release it: current gradually rises.
⑨
Push it again: current stops rising.
⑩
Release it: current drops gradually.
⑪
Push it again: current stops dropping, and then turn
to
②
.
⑫
If the torch trigger is not pushed after the current
begins to drop, the current will drop gradually till
arc stops.