Pág. 50
Double operation 4T mode:
⑤
Push the torch trigger: arc is ignited and current
reaches the initial value. The torch trigger can be
released at any time.
⑥
Release it: current rises gradually. The torch trigger
can be released at any time.
⑦
Push it again: current drops to pilot arc current
value. The torch trigger can be released at any time.
⑧
Release it: arc stops.
Cycle single operation mode without initial current:
⑤
Push the torch trigger: arc is ignited and current
rises gradually.
⑥
Release it: current drops to pilot arc current value.
⑦
Push it again: current rises gradually again, and
then turn to
②
.
⑧
If push the torch trigger and release it at once, arc
will stop.
Cycle single operation mode with initial current:
⑤
Push the torch trigger: arc is ignited and current
reaches the initial value.
⑥
Release it: current rises gradually.
⑦
Push it again: current drops to pilot arc current
value, and turn to
②
.
⑧
If release the torch trigger and push it at once, arc
will stop.
Inner timing operation mode:
⑤
Push the torch trigger: arc is ignited and current
rises gradually.
⑥
If release it within 1s, arc will stop; if release it after
1s, it will turn to
③
.
⑦
Push it again: current drops gradually, and arc
stops. The torch trigger can be released at any time.
⑧
If push the torch trigger again before arc stops, the
current will gradually rise again, and then turn to
③
.
1s
Outer timing operation mode:
④
Push the torch trigger: arc is ignited and current
rises gradually.
⑤
If release it within 1s, it will turn to
③
; if release it
after 1s, arc will stop.
⑥
Push it again: current drops gradually, and arc
stops.