GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
E
E
E
E
GB
GB
GB
GB
0
32
5
USER INTERFACE
CODE
SYMBOL
DESCRIPTION
L1
DC TIG mode:
Illumination shows that the following function has been activated: Q-START
AC TIG mode:
Illumination shows that the following function has been activated: AC WAVE IN MIX AC-DC
L2
DC TIG mode:
Illumination shows that the following function has been activated: DYNAMIC ARC
AC TIG mode:
Illumination shows that the following function has been activated: FUSIONE EXTRA
L3
DC TIG mode:
Illumination shows that the following function has been activated: MULTI TACK
AC TIG mode:
When this LED illuminates the following parameter can be set: AC FREQUENCY
AC TIG mode:
When this LED illuminates the following parameter can be set: AC TIG BALANCE
AC TIG mode:
When this LED illuminates the following parameter can be set: ELECTRODE DIAMETER
L4
This LED illuminates to confirm the presence of power on the output sockets.
L5
This LED illuminates to show an anomaly in the operating conditions.
See “ALARMS MANAGEMENT”(§ 9 page 36).
L6
This LED illuminates to show that the following welding mode is selected: TIG PULSED
L7
DC TIG mode:
When this LED illuminates the following parameter can be set: TIG SYNERGIC PULSE
When this is on, it means that the synergic mode is active and that the operator can set just the welding current while the other parameters
are automatically regulated by the machine. The synergy is optimised by angle welding.
L8
Illumination shows that the following function has been activated: High frequency arc strike (HF)
L9
This LED indicates that the current reference setting is imposed by the remote controller.
L10
Illumination shows that the following function has been activated: 2 times procedure
§ 13.1 page 48 / § 13.2 page 48
A flashing signal means the following function is activated: 2 times procedure
§ 13.7 page 49 / § 13.8 page 49
L11
Illumination shows that the following function has been activated: 4 times procedure
§ 13.3 page 48 / § 13.4 page 48
L12
Illumination shows that the following function has been activated: 4 times Bi-level procedure
§ 13.5 page 49 / § 13.6 page 49
L13
This LED illuminates to show that the following welding mode is selected: MMA
L14
This LED illuminates to show that the following welding mode is selected: TIG CONTINUOUS
L15
This LED illuminates to show that the following welding mode is selected: AC TIG
D1
Parameters/functions setting:
The displays show the value of the following parameter: WELDING CURRENT
Welding:
The display shows the effective amperes value during welding.
HOLD function:
The display shows the latest measured current value.