GALA MIG 257.
11
2. TRANSPORT AND INSTALLATION.
Knocks and sudden movements must be avoided when transporting the equipment. The equipment will always be
transported vertically. The packaging must be protected from water.
Wheels assembling.
3º
4º
2º
5º
1º
10º
10º
9º
8º
7º
6º
The welding equipment location must meet the following requirements:
- Place: Dry and ventilated, far enough away from the cutting area in order to prevent the metal dust caused
by the cutting process from getting into the equipment.
Electrical installation. Magnetothermal switch (Curve “D”)
.
GALA MIG 257
3P 16 A -
230V
3P 10 A -
400V
Power supply hose (RVK-1KV).
GALA MIG 257
Length
230 V
400 V
10 m
1,5 mm
2
1,5
mm
2
15-20 m
2,5 mm
2
2,5
mm
2
When leaving the factory the equipment is labelled with the voltage of use which has been chosen internally. In
dual-voltage three-phase equipment, the voltage can be changed on the inside of the equipment. Remove the
side panel. On the inside you will find a connection card (this is protected with a plastic cover). Make the
connection of the machine as indicated in Figure.
Voltage change system.
STANDARD EQUIPMENT (230/400 V)
SPECIAL EQUIPMENT (220/440 V)
230 V
400 V