To gain access to the different modes and control relay (by dial in)   

No. 

Function 

command 

Description 

Default 

Enter Programming Mode 

*12* [ password ] # 

Programming by calling   

1234 

Enter Monitoring Mode 

*13* [ password ] # 

To hear the surroundings where 

the intercom installed 

1212 

Enter Access control 

Mode (Trigger relay) 

*33* [ password ] # 

Password mode access option      5678 

Hold Relay 

*34* [ password ] # 

To hold relay to keep door 

opened 

5678 

Release Relay 

*35* [ password ] # 

To release relay for door close 

5678 

 

 

User commands to check system info & control relay via SMS 

No. 

Function 

Command 

Reply 

check signal strength 

*20#

 

Signal Level 0~31 from poor to best 

Service provide name, network 

Check stored numbers 

*21#

 

O [ number]…,I [ number]…..E (N) 

O

call button numbers list   

I

dial in to open numbers list 

E

End 

N

Next SMS 

Check relay status

 

*22# 

Relay [ status],Detect [ status ] 

Status: ON / OFF 

Trigger relay 

*33* [ password ] # 

 

No reply (default password:5678) 

(Latch on when relay is on hold status)

 

Hold relay 

*34* [ password ] # 

 

No reply   

(default password:5678)

 

Release relay 

*35* [ password ] # 

 

No reply 

(default password:5678) 

 

 

SMS data error 

 

(Only 0~9

*

# are available)

 

SMS Data Error 

 

 

Function code error     

Function Code Error 

 
 
 
 

Summary of Contents for SS91BV-M

Page 1: ...com 1 Revision E8 Jan 2015 GAINWISE TECHNOLOGY MANUAL DOORINTERCOM SS91BV M SS1204AV M GSM WCDMA INTERCOM ACCESS CONTROL SYSTEM For your protection read these instructions completely And keep them for...

Page 2: ...7 SS91BV M GSM INTERCOM OPERATION 8 Enter Listener Monitoring Mode 10 Enter Access Control Mode 10 Enter Programming Mode 10 Programming 11 Door Gate Release 12 Check GSM Signal Strength 14 Check Rela...

Page 3: ...roduct 2 Unplug all the connections of product before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 3 Do not use this product near water 4 Do not use this produ...

Page 4: ...ile call with you During the call you will be able to activate realty This SS91BV M GSM Intercom gives you the opportunity not only to know who is waiting at the entrance from a remote location but al...

Page 5: ...sion E8 Jan 2015 INSTALLATION This GSM Intercom is suitable for both flush and surface mounting Note For surface mounting you will have to remove the plastic enclosure before fitting main station into...

Page 6: ...SS91BV M GSM Intercom 6 Revision E8 Jan 2015 SS91BV M GSM Intercom Unit Wiring Diagram Call Button Speaker Microphone...

Page 7: ...is OFF before inserting the SIM card Carefully side the SIM holder in the OPEN direction insert the SIM and slide in the CLOSED direction to lock it in place 2 Antenna Install the antenna as high as p...

Page 8: ...ith the visitors During conversation press on your mobile for door open The relay switches can also be temporarily or permanently switched on or off by press and 1 Enter system menu There are three di...

Page 9: ...SS91BV M GSM Intercom 9 Revision E8 Jan 2015...

Page 10: ...fined numbers 3 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the password 4 The door will be opened after enter the correct password To open the door by passw...

Page 11: ...SMS must start with the pass code default 1234 in the following format 12 1234 Followed immediately by a command 4 To program a call button numbers DO NOT enter country code just the complete number a...

Page 12: ...se the following commands to program the unit Insert international country code 1 3 digits 71 country code Add a number up to 100 numbers 72 telephone number Delete a number 73 telephone number Delete...

Page 13: ...ng in to open SMS format to delete phone number 1 and 2 12 1234 730865683624 730865682554 SMS format to delete all numbers 12 1234 73 After the numbers are programmed you can also send the text messag...

Page 14: ...tatus SMS format 22 SMS Reply Relay ON Detect ON Relay Hold Detect GND Remark Terminal mark Detect see wiring diagram is for you to connect a door reed switch The gates would have a reed switch wired...

Page 15: ...ches 100 numbers default N 1 sending when it reaches 200 numbers Max Sending record when it reaches 100 numbers command code example 12 1234 830 2 Way of sending dial in numbers record via e mail or S...

Page 16: ...1234 85 11 SIM card number of SS91BV M for Clock date and time correction 12 1234 86 SIM No of SS91VB M 12 To delete SIM card number of SS91BV M for Clock date and time correction 12 1234 86 Remark w...

Page 17: ...ease relay for door close 5678 User commands to check system info control relay via SMS No Function Command Reply 1 check signal strength 20 Signal Level 0 31 from poor to best Service provide name ne...

Page 18: ...me level 0 4 3 7 Microphone Volume 4 microphone volume microphone volume level 0 4 3 8 Relay Time 51 relay time relay time 1 9999 sec 1 9 Call no answer time and divert to next number 52 no answer tim...

Page 19: ...o 24 Volt AC DC Operating Current Maximum 250 mA Typically 55mA GSM WCDMA Module Cinterion Simcom GSM WCDMA Frequency GSM 850 900 1800 1900 Mhz WCDMA 850 1900 or 900 2100 Mhz Physical size Face plate...

Page 20: ...number for dial in door release you NEED TO enter country code Command to use 12 1234 71 country code 72 phone number 72 phone number 72 phone number Example Ireland Country code 353 UK 44 USA 1 086 5...

Page 21: ...ct that the centre pin inside the antenna is intact and has not been pushed back inside the fitting Q The unit calls the first number but there is not enough time to answer before it diverts to the ne...

Page 22: ...ps on checking and improving reception Q The or key does not work when the intercom calls a phone A Check if you can hear the relay clicking at the gate when the or key is pressed during a call If it...

Reviews: