background image

3G Gate Opener                              1/17                                 

 

Revision V1.3B, Jan 2020 

 

 

GAINWISE TECHNOLOGY 

 

MANUAL 

3G GATE OPENER 

 

SS1806-3G-H 

 

2 outputs, 3 inputs 

 

 
 

 

 
 

Please read these instructions completely before use it 

Summary of Contents for SS1806-3G-H

Page 1: ...3G Gate Opener 1 17 Revision V1 3B Jan 2020 GAINWISE TECHNOLOGY MANUAL 3GGATEOPENER SS1806 3G H 2 outputs 3 inputs Please read these instructions completely before use it ...

Page 2: ...iring Diagram 5 5 4 Power Supply 6 6 LED INDICATORS 7 7 OPERATION 8 8 PROGRAMMING 8 8 1 Programming by dialing in 8 8 2 Programming by text message 9 9 ADMINISTRATOR NUMBER 10 10 CHECK SIGNAL STRENGTH 10 11 CHECK RELAY STATUS 10 12 HOW TO RESET THE UNIT WHEN YOU FORGET THE PASSWORD 10 13 CHECK ALL LOGGED DOOR ACCESS EVENTS VIA E MAIL OR SMS 11 14 USER COMMANDS 14 15 SPECIFICATIONS 17 16 QUICK PROG...

Page 3: ...ent and do not insert any objects through the Ventilation slots 7 Avoid using the equipment during an electrical storm There is a remote risk of electrical shock from lighting 2 BRIEF INTRODUCITON 3G Gate Opener is a 3Gswitch remote control system which can activate automatic gates with a free call from you mobile phone The users phone numbers are programmed into the device by SMS or call The devi...

Page 4: ...ty alarm On Off lights pumps and machines 4 STANDARD PACKING LIST Item Description Q ty Included Optional 1 3G Gate Opener 1 2 12 Volts DC power supply 1 3 Short Antenna 1 4 External Antenna 3 meter length 1 5 Bracket for antenna 1 6 Manual 1 5 INSTALLATION 5 1 SIM CARD INSTALLATION Fig1 You will need a regular voice and SMS text SIM card and capable of running on 2G 3G service 1 Use a standard SI...

Page 5: ...ption at the location where it wil be installled 2 If you use a 3 meters antenna install it as high as possible on the top of the pillar for best possilbe reception 5 3 WIRING DIGRAM Fig2 Fig3 Fig2 Interface instroduction 1 2 3 4 5 6 7 8 9 A B C GND IN1 Lo IN2 Lo IN3 Hi NO2 COM2 NC2 NO1 COM1 NC1 AC2 AC1 Fig1 ...

Page 6: ...G Gate Opener is designed to work with power supplies 12V 24V AC DC The power supply should be capable of supplying a constant current of no less than 1amp After a final check of wiring switch on the power allow 20 30 seconds for the unit to boot up and detect the network ...

Page 7: ... Standby In triggering setup time 17 Time 3 Trigger input 1 Input 1 active Sending SMS Standby In triggering setup time 15 Time 4 Power Power ON Power OFF X 5 Network status 3G device Busy or searching Module OFF Flashes once per second Standby 5 Network status 2G device Once 3 seconds standby Flashes once per second searching 6 Device status Standby Power OFF Flashes once per second No SIM insert...

Page 8: ...after enter correct password code Or just simply send SMS password code to the device 71 5678 Trigger relay 1 72 5678 Hold relay 1 73 5678 Release relay 1 74 5678 Trigger relay 2 75 5678 Hold relay 2 76 5678 Release relay 2 This is for door open option when telephone numbers not stored 8 PROGRAMMING Programming can be carried out either by text message or by dialing into the 3G Gate Opener 8 1 Pro...

Page 9: ...command format 12 1234 command Code1 command Code 2 command Code3 3 Each SMS must start with the pass code default 1234 in the following format 12 1234 Followed immediately by a command Program with the following format 12 1234 71 country code 72 relay phone number 72 relay phone number 72 relay phone number Relay 1 or 2 The passcode 12 1234 only needs to be put at the beginning of each new messag...

Page 10: ...pener the unit should reply with a signal strength code and service provider name The code will be between 0 31 means the signal level is from poor to best Example SMS format 21 1234 SMS reply Vodafone Signal Level 31 Signal is very strong 11 CHECK RELAY STATUS You can send SMS command code to check relay status SMS format 24 1234 SMS Reply Relay1 status Relay2 status status Hold release trigger I...

Page 11: ...ault N 1 sending when it reaches 200 numbers Max Sending record when it reaches 200 numbers command code example 12 1234 831 2 Way of sending a log of dial in numbers via e mail or SMS 12 1234 84 N N 0 no saving sending record N 1 via SMS 4 numbers limited SMS N 2 via E mail Sending record via email command code example 12 1234 842 3 GPRS parameters setting 40 1234 APN auth_type user name password...

Page 12: ... GPRS parameters N 1 reply e mail parameters N 2 reply recipient carbon copy N 3 reply e mail subject Check GPRS parameters setting Command code example 40 1234 9 Mobile number for receiving logged events via SMS 12 1234 85 mobile number 10 Delete mobile number for receiving logged events via SMS 12 1234 85 11 Clock Sync auto time calibration after power fail 12 1234 86 SIM phone number used in th...

Page 13: ...mmand codes in a single text message with SMS command format 12 1234 command Code1 command Code 2 command Code3 Example Mobile number for receiving logged events 0907967223 SIM phone number held within the opener 0948778458 12 1234 841 850907967223 860948778458 Send 44 1234 to check logged events Log format I Dial IN numbers N Next text massage E End text message ...

Page 14: ...me Activation time when input 1 is trigged Time 1 9999 seconds 0 sec no delay 7 15 Time Sending SMS duration when input 1 continues triggering Time 0 60 minutes 15 Time 8 16 Time Activation time when input 2 is trigged Time 1 9999 seconds 0 sec no delay 9 17 Time Sending SMS duration when input 2 continues triggering Time 0 60 minutes 0 min no delay 10 23 Time Activation time when input 3 is trigg...

Page 15: ...content max 100 characters Trigger1 is Active 20 32 1234 SMS content SMS message to be sent when input 2 is triggered SMS content max 100 characters Trigger2 is Active 21 33 1234 SMS content SMS message to be sent when input 3 is triggered SMS content max 100 characters Trigger3 is Active 22 71 country code To set country code Country code 1 3 digits UK 44 USA 1 886 23 72 relay phone number Store ...

Page 16: ...rator Signal Level 0 31 From poor to strong 2 22 1234 Reply stored numbers number1 number2 number3 E Next page N End 3 23 1234 Reply alarm contact numbers when inputs are triggered number1 number2 number3 4 24 1234 Check relay and inputs status Relay1 status Relay2 status Status hold release triggered IN1 status IN2 status IN3 status Status high low IN1 high IN2 high IN3 low standby IN1 low IN2 lo...

Page 17: ...ogram dial to open phone numbers 1150 numbers Note Program dial to open phone numbers you NEED TO enter country code and the complete number as you would dial it 12 1234 71 country code 72 relay phone number 72 relay phone number 72 relay phone number Relay 1 or 2 Example Ireland Country code 353 UK 44 USA 1 Do not use any leading zeroes 086 5683624 mobile number 1 086 5682554 mobile number 2 086 ...

Reviews: