There are 5 options:
•
00 Floor sensor:
run by floor sensor only
(default).
•
01 Room-in sensor:
uses the built-in
room sensor.
•
02 Room-in sensor and floor sensor:
uses the
built-in sensor with floor temperature limit.
•
03 Room-out sensor:
uses a remote air
sensor.
•
04 Room-out sensor and floor sensor:
uses
a remote air sensor with floor temperature
limit.
* If the thermostat is connected to the WiFi, it
will update the time automatically.
The thermostat can operate in two timer modes, Home or Office.
The Home schedule has two heating periods and two off periods,
whereas the Office mode has one heating and one off period.
See Page 13 for the full schedule and the pre-programmed
times, which can be adjusted to suit.
If you choose room sensor and floor
sensor, floor temperature limit must
be set to protect floor.
Home
Office
Clock
Floor Temperature Limit
Sensor Selection
Home or Office
Startup Wizard
Initial settings must be set when the unit is activated for the first time, this will ensure correct and efficient use of
your underfloor heating system.
Day Set
Hour Set
Minute Set
(If you choose both sensors)