background image

Pub. 42004-692L2C 

GAI-Tronics Corporation  400 E. Wyomissing Ave.  Mohnton, PA  19540  USA 

610-777-1374  

„

  800-492-1212  

„

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

G A I - T R O N I C S ®   C O R P O R A T I O N  

A   H U B B E L L   C O M P A N Y  

Model DEX-103 and DEX-203 

Hazardous Area Driller’s Intercom Stations 

Confidentiality Notice 

This manual is provided solely as an operational, installation, and maintenance guide and contains 
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-
Tronics retains all intellectual property and other rights in or to the information contained herein, and 
such information may only be used in connection with the operation of your GAI-Tronics product or 
system.  This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any 
third party. 

General Information 

Product Overview 

The Driller’s Intercom is a communications system 
designed to serve the needs of oil and gas industry on 
oil drilling platforms, especially in hazardous areas.  It 
provides all-call, group call, and point to point 
communications, and is available in digital and analog 
versions. 

The enclosure is rated IP56, and is factory sealed to 
ensure explosion-proof integrity. 

System Requirements and Limitations 

Each Driller’s Intercom system requires a Central 
Switch to operate.  The Central Switch must be located 
in a non-hazardous area.  The configuration parameters 
for all components of the system are set in the Central 
configuration. 

Each central switch can manage up to 16 digital or analog subscribers, and can be expanded to 32 
subscribers.  Central switches can be linked or a larger switch can be used for increased system size.  By 
combining central switches, the system is easily expanded at any time. 

All stations must be connected in a star configuration to the Central Switch, but power to the stations can 
be daisy-chained.  Please refer to the “Installation” section for the power cable and system cable distance 
limitations. 

Additional features and functions (not detailed in this manual) are available.  Refer to the Central Switch 
manual or contact a GAI-Tronics Corporation representative for more details. 

 

Figure 1.  Driller’s Intercom with Keypad 

Summary of Contents for DEX-103

Page 1: ...N T E N T S Confidentiality Notice 1 General Information 1 Product Overview 1 System Requirements and Limitations 1 Features and Functions 2 Available Models 2 Description of Major Components 2 Insta...

Page 2: ...ing platforms especially in hazardous areas It provides all call group call and point to point communications and is available in digital and analog versions The enclosure is rated IP56 and is factory...

Page 3: ...ac ATEX Description of Major Components The Driller s Intercom stations consist of a factory sealed enclosure top and a termination enclosure bottom Refer to Figure 1 for details The factory sealed co...

Page 4: ...e applying power verify that the bolts on the factory sealed section of the station are set at 30 ft lbs This station has a highly sensitive microphone that allows the user to communicate at a distanc...

Page 5: ...Pub 42004 692L2C MODEL DEX 103 AND DEX 203 DRILLER S INTERCOM STATIONS Page 4 of 13 f standard ioms current release 42004 instr manuals 42004 692l2c doc 11 10 Figure 2 Driller s Intercom Outline...

Page 6: ...Securely fasten the factory sealed and termination enclosures to the mounting location using steel mounting bolts and washers or washer head bolts hardware not included Conduit Installation Install t...

Page 7: ...nclosure Make all connections as described below NOTE All field wiring is to be completed in the termination enclosure bottom enclosure only NOTE Consult the National Electrical Codes and local codes...

Page 8: ...ated 24 V dc power source Additional power feeds may be required to increase the system distance and or the number of stations NOTE Isolated dc power sources must be used for this installation The 24...

Page 9: ...mination of a 2 conductor twisted pair cable on system terminals A and B only Analog stations require termination of a 4 conductor twisted pair cable A B twist C D twist on system terminals A D Refer...

Page 10: ...rd ioms current release 42004 instr manuals 42004 692l2c doc 11 10 System Interconnection Refer to Figure 6 for a typical system wiring diagram Consult the central switch manual for further details on...

Page 11: ...can be activated for a variety of conditions Refer to the Attendant Contacts section of the Central Switch manual for details 3 Depress and hold the T button or the footswitch and speak into the micro...

Page 12: ...decreased Increase the volume by simultaneously depressing the V and B buttons Decrease the volume by simultaneously depressing the V and C buttons The volume level setting range is between 0 and 9 an...

Page 13: ...ion Refer to the Volume Configuration section of the Central Manual for details High speaker volume Decrease the actual and or maximum volume settings in the configuration Refer to the Volume Configur...

Page 14: ...amplifier Frequency response 200 4 000 Hz 3 dB ref 1 kHz Speaker amplifier Output Class AB 18 watts min into 8 ohms with nominal supply voltage Frequency response 200 10 000 Hz 3 dB ref 1 kHz Distort...

Page 15: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: