Operation

 

The IP controller front panel contains three status LEDs. 

The IP controller requires an 

Elemec3

 console database version 3.3.3 or later.  Upgrade older database 

versions using the E3 Console application.  Refer to the E3 Console manual for additional details (see the 
Reference Documentation section). 

The LEDs operate according to the following table: 

Table 1.  Front Panel LED Indicators 

LED 

Indication 

PA

 

IN

 

USE 

Green

—Indicates the PA system is in use. 

Off—Not in use 

SYSTEM

 

STATUS

 

Green

—Normal operation 

Red—Fault condition—Utilize the 

Elemec3 

Portal application 

for detailed status information. 

Blinking Red—Fault acknowledged 

Amber—Non-critical fault 

PWR

 

Blue

—Power is on. 

Off—No power 

 

The IP controller displays system status via the E3 Portal application over an IP network.  Loss of 
connection to the data network constitutes a fault condition indicated by the 

SYSTEM

 

STATUS

 LED on 

the front of the controller. 

Reference Documentation

 

GAI-Tronics’ product documentation is located on the GAI-Tronics website at 

https://www.gai-

tronics.com

. 

Document Title 

Publication No. 

Elemec3 Console Manual—Version 3.0 ........................................................................................ 42004-550 

Elemec3 Portal System-Administration Utility—Version 3.1 ....................................................... 42004-485 

Specifications

 

Electrical 

PoE: 

PoE, IEEE 802.23af Class 0  ....................................................................... 4.3 W/15.4 W (idle / maximum) 

PoE Plus, IEEE 802.3at Class 4 .................................................................... 4.3W/25.5 W (idle / maximum) 

Ethernet 

Ethernet ................................................................................................................................ 100/1000 Base-T 

Speed ...................................................................................................................................... 100/1000 Mbps 

Cable ............................................................................................................................. Category 5e or better 

Summary of Contents for 013-02-0096-001

Page 1: ...ty Notice 1 General Information 1 Important Safety Instructions 2 Front Panel Indicators Control 3 Rear Panel Connections 3 Internal 3 Installation 3 Safety Guidelines 3 Location 4 Desktop 4 Rackmount...

Page 2: ...ly to any third party General Information The Model 013 02 0096 001 IP Controller is the principal component of an IP PAGA public address and general alarm system This standalone IP controller is suit...

Page 3: ...inputs and outputs are available via IP MIMs monitored input modules or IP MRMs monitored output modules Connect IP access panels for speech broadcasts and manual alarm emergency message activation Ad...

Page 4: ...3 IP controller Rear View Internal The IP controller contains one primary internal component see Figure 4 E3 IP Controller PCBA Central processing unit digital communication speech recording and play...

Page 5: ...eet and set the unit on a stable level surface Rackmount Use GTC Kit No 12625 001 to mount the IP controller in an standard EIA 19 inch rack see Figure 5 The controller is 1 75 inches tall 1 U of rack...

Page 6: ...es link status yellow LED indicates activity 2 Terminate the connector in accordance with the T 568B wiring method Earth The E3 IP controller requires bonding to earth ground 1 Install a ring lug on a...

Page 7: ...ion and maintenance of the installed Elemec3 IP access panels Inputs Outputs The IP controller has eight unsupervised inputs and eight outputs to initiate events in the system see Figure 3 Connect eac...

Page 8: ...ec3 Portal application for detailed status information Blinking Red Fault acknowledged Amber Non critical fault PWR Blue Power is on Off No power The IP controller displays system status via the E3 Po...

Page 9: ...nput level 0 775 V RMS Input impedance 50 k at 1 kHz Bandwidth 300 3 400 Hz 0 3 dB reference to 1 kHz Isolation 500 V RMS Control Input N O dry contact Open circuit voltage 3 3 V dc typical Short circ...

Page 10: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: