15
ENGLISH
>
Pull the milk frother off to remove it from the steam wand.
The milk frother dispensing spout comprises four parts that must be disassembled:
1. Suction tube
2. Milk frother lid
3. Milk frother
4. Rubber cover
>
Remove the suction tube (1) from the milk frother (3).
>
To detach the milk frother dispensing spout, press the sides and remove it (3) by
applying light lateral movements.
>
Remove the rubber cover (4).
>
Clean all the components thoroughly with lukewarm water.
All the individual components can be washed in the dishwasher.
Reassembly phase
>
Perform the sequence of operations described in the previous
“Milk frother dispensing
spout disassembly phase”
in reverse order and reassemble all the components of the
milk frother.
7.5 Descaling cycle
When the CALC CLEAN symbol is displayed, it is necessary to descale the machine.
If this is not done, the machine may stop working correctly: in this case, repairs are
NOT covered by the warranty.
The descaling cycle has a duration of roughly 30 minutes. It consists of a proper
cleaning cycle, with the Gaggia descaling product, followed by a rinse cycle.
Do not remove the brew group during the descaling process.
Do not drink the descaling solution or the products resulting from the descaling cycle.
Use exclusively the Gaggia descaling solution. The use of other products may damage
the machine and leave residue in the water. The Gaggia descaling solution is sold
separately. For further details please refer to the
“10.1 Maintenance products”
chapter.
Preparation phase
>
Press the side buttons.
>
Remove the drip tray.
>
Remove the coffee grounds drawer and empty it.
>
Empty and wash the drip tray.
>
Restore all the components.
>
Place a large container (1.5 l) under the dispensing spout.
>
If installed, remove the milk frother from the steam wand.
Descaling phase
If the water filter is present, extract the filter from the water tank and
replace it with the original small white filter.
>
Pour all the descaling solution in the water tank.
>
Then fill the tank with fresh water to the CALC CLEAN level.
>
Put the water tank back in the machine.
>
Press the MENU button and scroll the menu to go to the descaling function.
>
Press the OK button to select the descaling function.
>
Press the OK button to launch the descaling cycle. The machine starts dispensing the
descaling solution at intervals. The bar shows the cycle progress status.
The cycle can be paused by pressing the ESC button and restarted by pressing the OK
button. This makes it possible for the user to empty the container or leave for a while.