5
Remove the residues drawer.
6
Thoroughly rinse the brew group using lukewarm water. Carefully wash the
upper filter .
7
Let the brew group dry in the air.
Note
: to avoid the build-up of fibres in its interior, do not dry the brew group with
cloths.
4
Press the PUSH lever (1) and pull the handle of the brew group to remove it
from the machine (2).
Cleaning the brew group with the Coffee Clean tablets
Warning
: while cleaning the machine, only use Gaggia tablets for the removal of fat
coffee residues since they do not perform a descaling action.
1
Place a container under the coffee dispensing spout.
2
Press the AROMA STRENGTH button and select pre-ground coffee.
3
Insert a Coffee Clean tablet into the pre-ground coffee compartment.
4
Press the LONG ESPRESSO button. The machine dispenses water from the
coffee dispensing spout.
5
When the progress bar is halfway, switch the power button located on the back
of the machine to “0”.
6
Let the solution for the removal of fat coffee residues act for about 15 minutes.
7
Switch the power button to “I”. Press the Stand-by button.
8
Wait for the machine to perform an automatic rinse cycle.
9
Perform the “Brew Group Cleaning under Running Water” operation.