Installation Procedure

Prepare Installation Space

Create the cut-out in the countertop for one or several 
Vario appliances according to the installation diagram. 
The angle of of the cut surface to the countertop must 
be 90°.

After creating cut-out, remove shavings. Seal cut 
surfaces in a heat-resistant manner.

Some solid surface countertops require special 
installations. For example, heat reflective tape and 
rounded corners may be necessary. Contact the 
countertop manufacturer for instructions specific to 
your countertop.

Observe minimum distance between appliance 
underside and furniture parts of 

3

/

8

" (10 mm).

When installing multiple Vario appliances: 

Take into 

account space requirement for VV 200 connection 
strip between the appliances. Appliances can also be 
installed in individual cut-outs, bearing in mind a 
minimum distance between the appliances of 1

9

/

16

(40 mm).

Install Appliance

9

WARNING

Before you plug in an electrical cord or turn on 
power supply, make sure all controls are in the 
OFF position.

1

Make a mark exactly in the center of the cut-out. 
Fasten the mounting rails to the front and rear 
edge of the cut-out. The leading edges of the 
mounting rails must lie upon the countertop. The 
center marking of the mounting rails must 
correspond precisely with the center marking of 
the cut-out.

Note: 

For stone countertops, adhere the 

mounting rails with temperature-resistant duel-
component adhesive (metal on stone).

2

For combination with the VD 201 appliance cover: 
Mount appliance cover to appliance prior to 
installation (see VD 201 Installation Instructions).

3

Insert appliance in cut-out. The snap-in pins on 
the appliance must lie precisely on the clamp 
springs. Press appliance firmly into the cut-out. 

The snap-in pins on the appliance must snap into 
the clamp springs.

Connect Electrical Supply

Refer to data plate for more information. See "Service" 
for data plate location.

The branch-circuit breakers ampacity, the wire sizes 
and the connections must be conform to the 
requirements of the National Electrical Code or 
Canadian Electrical Code and all local codes and 
ordinances.

Attach flexible conduit to the junction box. Connect 
the lead wires to the junction box supply wires in 
proper phase:

black (L1) to black

red (L2) to red

green to ground