4.
Mark the unit cut-out in accordance with the installa-
tion diagram.
5.
Ensure that the angle of the cut surface to the work-
top is 90°.
6.
Remove dust and residues from the cut-out work.
Seal the cut surfaces so that they are heat-resistant
and waterproof.
7.
Provide an intermediate floor between the appliance
and the top drawer.
8.
Observe the clearance between the intermediate
floor and the worktop.
Creating ventilation openings
Requirement:
The appliance requires sufficient ventila-
tion from below to function correctly.
1.
Make a unit cut-out in the upper area on the rear of
the unit.
2.
Observe the minimum clearances.
3.
If there is no minimum clearance at the rear of the
unit, make a unit cut-out in the bottom of the unit.
4.
Ensure that the base of the unit is sufficiently ventil-
ated.