background image

변경한 후에 기능을 점검하십시오 .     

불꽃에서 노란색 불꽃 끝이 보이지 않아야 합니다 . 큰 연소에서 

작은 연소로 빠르게 돌릴 때 , 불꽃이 꺼지지 않아야 합니다 .
참고 . 변경된 가스 종류의 스티커를 기종 명세판에 붙여 

놓으십시오 .

en

Ú

 Installation instructions

Important notes

Read these instructions carefully and keep them in a safe place. 

Safety during use can only be ensured if the appliance is fitted 

correctly according to these installation instructions. The installer 

is responsible for ensuring that the appliance operates perfectly at 

the point of installation.

The appliance must be connected to the mains only by a licensed 

and trained technician.

Before carrying out any type of work, turn off the electricity and gas 

supply.

For installation, currently applicable building regulations and the 

regulations of local electricity and gas suppliers must be observed 

(e.g. Germany: DVGW-TRGI/TRGF; Switzerland: SVGW; Austria: 

ÖVGW-TR).

For conversion to another type of gas, please call the after-sales 

service.

ã=

Risk of gas escape!

After connecting the appliance to the gas supply, always check the 

connection for leak tightness. The manufacturer accepts no 

responsibility for the escape of gas from a gas connection which 

has been previously tampered with.
Ensure sufficient air exchange in the room where the appliance is 

installed. Up to 11 kW total output:

Minimum volume of the room where appliance is installed: 20 m³

A door leading to the open air or a window which can be opened.

Up to 18 kW total output:

Minimum volume of the room where appliance is installed: 2 m³ 

per kW total output.

A door leading to the open air or a window which can be opened.

An extraction hood into the open air. Minimum displacement 

volume of extraction hood: 15 m³/h per kW total output.

The installation system must incorporate an all-pin isolating switch 

with a contact opening of at least 3 mm, or the appliance should be 

connected to the mains via a safety plug. The plug must remain 

accessible after installation is complete.

Specifications on the rating plate showing voltage, type of gas and 

gas pressure must agree with the local mains connection 

conditions.

Do not kink or trap the mains connection cable.

This appliance corresponds to appliance class 3 (for installation in 

a kitchen unit). It must be fitted according to the installation 

drawing. The wall behind the appliance must be made of non-

flammable material.

This appliance is not intended for operation with an external timer 

or an external remote control.

Do not install this appliance on boats or in vehicles.

Preparing the furniture

The surrounding kitchen unit must be heat-resistant to at least 

90 °C. The stability of the unit must be maintained after producing 

the cut-out.

Produce the cut-out for one or several Vario appliances. Proceed 

as shown in the installation sketch. The angle between the cut 

surface and the worktop must be 90°.

After producing the cut-out, remove the shavings. Seal the cut 

surfaces to make them heat-resistant.

Observe a minimum clearance between the appliance housing 

and parts of the unit of 10 mm.

When fitting several Vario appliances: allow for the additional 

space required for the connecting strip VV 200. Appliances can 

also be fitted in individual recesses, if a minimum clearance of 
40 mm between the appliances is observed.

Fitting the appliance

1.

Mark the centre of the recess exactly. Fit the mounting rails to the 

front and rear of the recess. Make sure the lugs of the mounting 

rails lie on the worktop. The centre marking on the mounting rails 

must be precisely flush with the centre marking of the recess.
Note: when fitting the appliance in a stone worktop glue on the 

mounting rails with a temperature-resistant two-component 

adhesive (metal on stone).

2.

For combination with the appliance cover VD 201: secure the 

appliance cover on the appliance before installation (refer to the 

installation manual of VD 201).

3.

Lower the appliance into the cut-out. The snap-in pins on the 

appliance must lie exactly on the catch springs. Firmly press the 

appliance into the cut-out. The pins on the appliance must snap 

into the catch springs.

Removing the appliance

Disconnect the appliance from the power and the gas supply. 

Push out the appliance from below.
Caution!

Risk of damage! Do not lever out the appliance from above.

Gas connection

The gas connection must be located in a position where the stop 

tap is accessible.

Using one of the R½'' (for appliance side) connection elbows 

provided, connect the appliance with the associated gasket to a 

fixed connection pipe or a gas safety hose. If the gas safety hose 

is not (or only partly) made of metal, the ambient temperature must 

not exceed 70°K. In the case of a gas safety hose made entirely of 

metal, the permissible ambient temperature is 115°K. The gas 

safety hose must be routed so that it does not come into contact 

with moving parts of the kitchen unit (e.g. drawers).

Electrical connection

Check that the appliance has the same voltage and frequency as 

the electrical installation system.

The hob is delivered with a mains cable, with or without plug, 

depending on model.

Only connect the appliance to sockets which have been fitted and 

earthed according to regulations.

The appliance corresponds to type Y: the mains connection cable 

must only be replaced by the after-sales service. Check the cable 

type and minimum cross section.

Technical data / nozzle table

Total connected load natural gas 6 kW

Total connected load bottled gas (LPG) 5 kW

Total connected load electric 0.8 VA
Nozzle table wok burner

Conversion to another type of gas

This gas hob corresponds to the categories specified on the rating 

plate. It is possible to convert the appliance to any of the gases 

listed on the plate by changing the nozzles. The modification kit 

can be ordered via our after-sales service. Depending on the 

model the parts required may beincluded in the scope of delivery. 

The conversion must be carried out by a licensed and trained 

technician.

Before carrying out the conversion, turn off the electricity and gas 

supply.

Gas

LNG

LPG

Pressure

20 mbar

25-28 mbar

C Nozzle, full burn, outer

173

110 A

A Nozzle, low burn, outer

81

57

D Nozzle, full burn, inner

60

42

B Nozzle, low burn, inner

45

31

Air gap adjustment, outer

3 mm

0 mm

Air gap adjustment, inner

*

*

Total connected load

6 kW

5 kW

Total consumption

0.57 m³/h

360 g/h

*open, fixed