IMPORTANT SAFETY INSTRUCTIONS

These instructions shall also be available on website

: www.whirlpool.eu

YOUR SAFETY AND THE SAFETY OF OTHERS ARE VERY IMPORTANT

This manual and the appliance itself provide important safety messages, to be read and observed at all times.  

  This is the safety alert symbol, pertaining to safety, which alerts users to potential hazards to themselves and others.

All safety messages will follow the safety alert symbol and either the terms:

Indicates a hazardous situation which, if not avoided, will cause serious injury.

Indicates a hazardous situation which, if not avoided, could cause serious injury.

 

All Safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

-  The appliance must be disconnected from the power supply before carrying out any installation work.

-  Installation and maintenance must be carried out by a qualified technician, in compliance with the manufacturer’s instructions and local safety regulations. Do not repair 

or replace any part of the appliance unless specifically stated in the user manual.

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage or injury.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance.

What to do if you smell gas:

- Do not try to light any appliance.

- Do not touch any electrical switch.

- Do not use any phone in your building.

- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

- Use appliance in well ventilated rooms only.

The electrical and gas connections must comply with local regulations.

•  When the hob is installed, provide a multi-pole circuit breaker with a contact separation of at least 3 mm, that 

provides full disconnection.

•  Regulations require that the appliance is grounded.

• 

The power cable must be long enough for connecting the appliance, once fitted in its housing, to the power supply.

• 

Use only flexible or rigid metal hose for gas connection.

• 

If necessary, the electrical power cable must be replaced exclusively with a power cable having identical 

characteristics to the original supplied by manufacturer (type H05V2V2-F 90°C or H05RR-F). This operation 

must be performed by a qualified electrician.

•  The manufacturer cannot be held responsible for any injury to persons or animals or damage to property arising 

from failure to comply with these requirements.

• 

Do not use multiple plug adapters or extension cords.

• 

Do not pull the power cable to disconnect it from the electrical supply.

•  The electrical components must not be accessible to the user after installation.

• 

Do not touch the appliance with any wet part of the body and do not operate it when barefoot.

• 

This hob (class 3) is designed solely for private household use for cooking food. Do not use this appliance as 

a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating 

of the hob. The Manufacturer declines all responsibility for inappropriate use or incorrect setting of the controls.

•  The appliance and its accessible parts become hot during use. Very young (0-3 years) and young children (3-8 

years) shall be kept away unless continuously supervised. Children from 8 years old and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience and knowledge can use this appliance 

only if they are supervised or have been given instructions on safe appliance use and if they understand the 

hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made 

by children without supervision.

 DANGER

 WARNING

 WARNING

4000 108 02632

EN

Manufacturer: Whirlpool Europe S.r.l. - Single Shareholder - Viale G. Borghi, 27 21025 Comerio (VA) ITALY

BUILT-IN GAS HOB INSTRUCTIONS

Summary of Contents for AKR 350

Page 1: ...provide a multi pole circuit breaker with a contact separation of at least 3 mm that provides full disconnection Regulations require that the appliance is grounded Thepowercablemustbelongenoughforconnectingtheappliance oncefittedinitshousing tothepowersupply Use only flexible or rigid metal hose for gas connection If necessary the electrical power cable must be replaced exclusively with a power ca...

Page 2: ...ore installation make sure that the local gas delivery conditions nature and pressure are compatible with the settings of the hob see the rating plate and injector table the outer surfaces of the furniture or appliances adjacent to the hob are heat resistant according to local regulations this appliance is not connected to a fume exhaust device It shall be installed in accordance with current inst...

Page 3: ...B Using a socket spanner of the appropriate size unscrew the injector C unscrew the injector to be replaced Replace it with the injector suitable for the new type of gas Re assemble the injector in D If you have a multiple crown burner use side spanner to replace the injector E Before installing the hob remember to affix the gas calibration plate supplied with the injectors in such a way that it c...

Page 4: ...NING THE HOB PARTS Grids burner caps and burners can be removed to be cleaned Clean them by hand with warm water and non abrasive detergent removing any food residues and checking that none of the burner openings is clogged Rinse and dry Refit burners and burner caps correctly in the respective housings When replacing the grids make sure that the panstand area is aligned with the burner Models equ...

Page 5: ...f the burners turn the relative knob anti clockwise to the maximum flame setting Press the knob against the control panel to ignite the burner After the burner has ignited keep the knob pressed for about 5 10 seconds to allow proper device operation This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally because of sudden draught an interruption in the g...

Page 6: ...1 Rapid 125F2 3 00 332 l h 0 60 18 25 33 Semi rapid 96F2 1 75 194 l h 0 35 Auxiliary 71F1 1 00 111 l h 0 30 LIQUEFIED PETROLEUM GAS Butane G30 Propane G31 Rapid 85 3 00 218 g h 0 60 25 30 35 Semi rapid 63 1 75 127 g h 0 35 Auxiliary 50 1 00 73 g h 0 30 Type of gas used Model configuration 4 BURNERS Rated thermal flow rate kW Total rated consumption Air required m3 for burning 1 m3 of gas G20 25 mb...

Page 7: ...szüléket kizárólag jól szellőztetett helyiségekben használja Azelektromosésgázcsatlakoztatásmegkell hogyfeleljenahelyirendelkezéseknek Atűzhelylapüzembehelyezésekoregytöbbpólusúmegszakítókapcsolótkellhasználni melynélazérintkezők távolsága legalább 3 mm ami teljes leválasztást biztosít Az előírások értelmében a készüléket földelni kell A elektromos kábelnek elég hosszúnak kell lennie a helyére bes...

Page 8: ... e lásd a törzslapot és a fúvókatáblázatot a tűzhelylappal szomszédos konyhabútorok vagy készülékek külső felülete hőálló e a helyi rendelkezésekkel összhangban a készülék nincs csatlakoztatva égésanyagokat elvezető berendezéshez Üzembe helyezését az érvényes üzembe helyezési előírásokkal összhangban kell végezni Külön figyelmet kell szentelni a szellőzésre vonatkozó követelményeknek az égéstermék...

Page 9: ...elje ki az égőfejeket B Egy megfelelő méretű csőkulcs segítségével csavarozza ki a kicserélendő fúvókát C Cserélje ki az új gáztípushoz megfelelő fúvókával Szerelje vissza a fúvókát D Többkoronás égőfej esetén egy csavarkulcs segítségével cserélje ki a fúvókát E Atűzhelylapbeüzemeléseelőttnefelejtseelfelragasztaniafúvókákhozmellékeltgázkalibrálásitáblát oly módon hogy az elfedje a gázkalibrálásra ...

Page 10: ...ÉSZEINEK TISZTÍTÁSA Arácsok az égőfejsapkák és az égőfejek a tisztításhoz levehetők Kézzel melegvízésnemdörzshatásúmosogatószersegítségéveltisztítsamegezeket eltávolítvaazételmaradékokat ésleellenőrizve hogyazégőfejekegyetlen nyílása se legyen eltömődve Öblítse át és törölje szárazra Az égőfejeket és az égőfejsapkákat megfelelően helyezze be foglalatukba Arácsok visszahelyezésekor ügyeljen arra ho...

Page 11: ...TŰZHELYLAP TELJES TERÜLETE FELFORRÓSODHAT Egy égőfej meggyújtásához forgassa el a megfelelő gombot óramutató járásával ellentétes irányba a maximális lángra Nyomja a gombot a kezelőlap felé hogy az égőfej begyulladjon Ha az égőfej már meggyulladt tartsa még lenyomva a gombot kb 5 10 másodpercig hogy lehetővé tegye az eszköz megfelelő működését Az égőfej biztonsági rendszere lekapcsolja az égőfej g...

Page 12: ...ZETES GÁZ G25 1 Gyors 125F2 3 00 332 l óra 0 60 18 25 33 Közepes 96F2 1 75 194 l óra 0 35 Kiegészítő 71F1 1 00 111 l óra 0 30 FOLYÉKONY GÁZ bután G30 propán G31 Gyors 85 3 00 218 g h 0 60 25 30 35 Közepes 63 1 75 127 g h 0 35 Kiegészítő 50 1 00 73 g h 0 30 Használt gáz típusa Kivitel 4 GÁZRÓZSA Névleges áramlási sebesség kW Teljes névleges fogyasztás 1 m3 gáz elégetéséhez szükséges levegő m3 G20 2...