28
Filter – Product Data Sheet
Performance Data Sheet For Filter Model 9000 077 095
Using Replacement Cartridge 9000 077 104
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances liste below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal
to the permissible unit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
System tested and certified by NSF International in Model 9000 077 095 against NSF/ANSI Standard 53 for
the reduction of Cysts and Turbidity and against Standard NSF/ANSI 42 for the reduction of Chlorine Taste
and Odor;
Nominal Particulate Class I
to a capacity of 739.68 gallons (2800 liters).
Application Guide lines/Water Supply Parametets
Water pressure:
30–120 psi (207–827 kPa)
Water temperature
*
:
33 ºF–100 ºF (0.6 ºC–38 ºC)
Service flow: 0.75 gpm (2.83 lpm)
Systems must be installed and operated in accordance
with manufacturer's recommended procedures and
guidelines
Change filter at least every 6–9 months.
Flush new filter for 5 minutes.
See warranty card for complete details.
Do not use with water that is microbubgically unsafe
or of unknown quality wihtout adequate disuft:
ctun before or after the system. Systems certified
for cyst reduction may be used on disufected waters
that may contau filterable cysts.
Entire System (excluding disposable cartridges)
is warrantied for a period ofone year.
Disposable cartridges are Warrantied for defects
u material and workmanship only.
Service life of disposable filter cartridges varies with
local water conditions and is thus not warrantied.
For estimated costs of replacement elements please visit
your local appliance dealer or parts dis tributor.
Manufactured by:
Cuno Engineered Products
1000 Apollo Road
Eagan, MN 55121-2240 U.S.A.
Substance
Average
Influent
Concentration
Influent
Challenge
Concentration
mg/L
Product
Water
Concentration
Average
%
Reduction
Maximum
Permissible
Product Water
Concentration
Max.
Effluent
Min. %
Reduction
NSF
Test
Cysts *
166.500
Min. 50.000/L
1
99.99
99.95
1
99.99
511077-03
Turbidity
10.7
11 x 1 NTU
0,31
97.10
0.5 NTU
0.49
95.42
511078-03
Particulate
Class I Particle site:
> 0,5 to < 1 µm
5.700.000
At least
10.000
particles/ml
30.583
99.52
> 85 %
69.000
98.9
511079-03
Chlorine taste
and odor
1.9
2,0 mg/L ±10%
0.05
97.3
> 50 %
0.06
96.84
511081-03
* Based on the use of Cryptosporium parvum oocysts.