background image

6

Flush Installation Dimensions and Clearances

Figure 4

Figures 2, 3 and 4 contain many Microwave Built-in 
Drawer measurements for reference when planning the 
drawer’s location.

This Microwave Built-in Drawer can be installed below any 
electric or gas wall oven.

  NOTICE: Always allow sufficient power cord length to 

the electrical outlet to prevent tension.

  Always check electrical codes for requirements.

23

1

/

2

"

(597 mm)

21

7

/

8

"

(555 mm)

Base min.

depth

27"

(686 mm)

1"

(25 mm)

1"

(25 mm)

36"

(914 mm)

24

3

/

16

"

(614 mm)

22

1

/

8

"

(562 mm)

Frontview cut out

Cleat

14

5

/

8

" (371 mm)

16

5

/

8

(422 mm)

cutout

6" (152 mm)

4" (102 mm)

5" (127 mm)

2

1

/

4

" (57 mm)

1

5

/

8

(41 mm)

1

/

2

(13 mm)

visible

area

1

/

4

(6 mm)

base

thickness

*  Suggested location of electrical outlet

**  Anti-Tip Block

***  Base should support up to 100 lbs

**** Sides should be finished and extend back to cleat.

 

Cleats should also be finished, as they may be 

 

visible after installation.

(Cleats are not included with unit.)

*

**

***

****

Anti-Tip Block

Normal Installation Steps

Anti-Tip Block Installation Instructions

The anti-tip block reduces the risk of drawer tipping 
when installed properly. Install the anti-tip block 
14 13/16 inches above the installation opening floor 
(where the unit will sit) for a standard installation or 
14 5/8 inches for a flush 
installation. The 6 -inch 
Anti-Tip block must be 
provided by the installer. 
See Figure 3 (standard 
installation) or Figure 4 
(flush installation) and 
Figure 5. The Anti-Tip 
block prevents serious 
injury that might result 
from spilled hot liquids.

Figure 5

4"

5"

Suggested electrical

outlet location*

Anti-Tip

block

6"

3

1

/

2

"

If the Microwave Built-in Drawer is ever moved to a differ-
ent location, the Anti-Tip block must also be moved and 
installed. If the anti-tip block is to be anchored to the 
wall make certain that the screws holding it penetrate 
into the structural members (studs) behind any covering 
such as drywall. 

CAUTION

Make sure that the screws do not contact any wiring or 

plumbing that may be present in the wall.

WARNING

The unit can tip and cause spills and potential 
burns or other injuries if the anti-tip block is not 
installed correctly.

Summary of Contents for MW 420 620

Page 1: ...Gaggenau Installation instructions 2 Instructions d installation 9 Instrucciones de instalaci n 14 MW 420 620 Microwave Built in Drawer Micro ondes int gr dans le tiroir Microondas gaveta Incorporado...

Page 2: ...with the door open since open door operation can result in harmful exposure to microwave energy It is important not to defeat or tamper with the safety interlocks b Do not place any object between the...

Page 3: ...the outlet box does not meet Electrical Requirements a qualified electrician should be employed to correct any deficiences Clearances and Dimensions z z For safety considerations do not install Microw...

Page 4: ...s Use caution when reaching behind or under appliance z z Read and understand the contents of this Installation Manual before installing the Microwave Built in Drawer z z Remove all packing material b...

Page 5: ...m 217 8 556 mm 38 3 8 974 mm 145 8 371 mm 16 5 16 414 mm 14 5 8 372 mm 23 1 2 597 mm 24 or 27 610 or 686 mm 36 914 mm 221 8 562 mm Frontview cut out Suggested location of electrical outlet Anti Tip Bl...

Page 6: ...nstallation Steps Anti Tip Block Installation Instructions The anti tip block reduces the risk of drawer tipping when installed properly Install the anti tip block 14 13 16 inches above the installati...

Page 7: ...person Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach Always check electrical codes for requirements Drawer Insta...

Page 8: ...al AVERTISSEMENT Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou un choc peuvent causer des dommages mat riels ou corporels PR CAUTIONS POUR VITER LE RISQUE D...

Page 9: ...la zone de prise est correctement mise la terre S il n est pas correcte ment mise la terre ou si la bo te de sortie ne r pond pas aux exigences lectriques un lectricien qualifi doit tre utilis e pour...

Page 10: ...es d installation avant d installer le Tiroir micro ondes z z Retirer tous les mat riaux d emballage avant de con necter au secteur z z Le propri taire et l installateur sont responsables d assurer la...

Page 11: ...414 mm Environ 46 po 1 168 4 mm 145 8 po 372 mm 23 1 2 po 597 mm 24 po ou 27 po 610 ou 686 mm 36 po 914 mm 22 1 8 po 562 mm D coupe vue de face Emplacement sugg r de la prise lectrique Bloc antibascu...

Page 12: ...o 25 mm 36 po 914 mm 243 16 po 614 mm 221 8 po 562 mm D coupe vue de facet Tasseau 14 5 8 po 371 mm 165 8 po 422 mm D coupe 6 po 152 mm 4 po 102 mm 5 po 127 mm 2 1 4 po 57 mm 15 8 po 41 mm 1 2 po 13 m...

Page 13: ...mentation fourni avec l appareil V rifiez toujours les normes et le code lectriques de votre r gion Installation du tiroir 1 Placer le four pr s de l ouverture du mur ou de l armoire Brancher le cordo...

Page 14: ...E ELECTRICIDAD z z LEA Y GUARDE ESTAS INSTRUCIONES PARA FUTURA REFERENCIA Advertencia especial 14 Espacios libres y dimensiones 15 Desembalaje de su Microondas gaveta Incorporado 15 Notas importantes...

Page 15: ...e todos los materiales de embalaje que est n dentro de la gaveta NO RETIRE LA CUBIERTA DE LA GU A DE ONDAS ubicada en la parte superior del Microondas gaveta Incorporado z z Verifique que la gaveta no...

Page 16: ...n sugerida del tomacorriente Bloque antivuelco La base debe soportar hasta 100 libras 1413 16 376 mm 6 152 mm 4 102 mm 5 127 mm 3 1 2 89 mm 1 1 2 38 mm 7 8 22 mm de sobreposici n 1 2 13 mm rea visible...

Page 17: ...ableado o tuber as que puedan estar presentes en la pared ADVERTENCIA La unidad puede voltearse y causar derrames y posibles quemaduras u otro tipo de lesiones si el bloque antivuelco no est instalado...

Page 18: ...asta donde se pueda extender el cable el ctrico Siempre verifique los c digos el ctricos para ver los requisitos Instalaci n de la gaveta 1 Coloque el Microondas gaveta Incorporado al lado de la abert...

Page 19: ......

Page 20: ...966545 TINSLB042MRR0 Gaggenau BSH Home Appliances Ltd 1901 Main Street Suite 600 Irvine CA 92614 1 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen GER...

Reviews: