21
Nozzle, full burn, outer
1.50
1.05
Nozzle, low burn, outer
0.65
0.45
Nozzle, full burn, inner
0.40
0.29
Nozzle, low burn, inner
0.42
0.28
Air gap adjustm. outer [mm]
0
2
Air gap adjustm. inner [mm]
open, fixed
open, fixed
Countries
US CA
US CA
Gas family
Natural gas
LPG/Prop.
Pressure
6” W
.C. (1.5 kPa)
10” W.C. (2.5 kPa)
T
otal output (5 burners)
58,000 BTU (17 kW)
58,000 BTU (17 kW)
Nozzle table large burner
Nozzle, full burn, outer
0.97
0.68
Nozzle, low burn, outer
0.48
0.34
Nozzle, full burn, inner
0.40
0.29
Nozzle, low burn, inner
0.42
0.28
Air gap adjustm. outer [mm]
0
open at maximum
Air gap adjustm. inner [mm]
open, fixed
open, fixed
Nozzle table small burner