Fault
Cause and troubleshooting
E:9210 lights up.
Lower spray arm is not correctly fitted.
▶
Fit the lower spray arm correctly.
E:9240 lights up.
Filters are soiled or blocked.
▶
Clean the filters.
→
A different error code
appears in the display
window.
E:0100 to E:9010
A technical fault is present.
1.
Press .
2.
Unplug the appliance or switch off the fuse.
3.
Wait at least 2 minutes.
4.
Insert the mains plug of the appliance in a socket
or switch on the fuse.
5.
Switch the appliance on.
6.
If the problem occurs again:
‒
Press .
‒
Turn off the water tap.
‒
Pull out the mains plug.
‒
Contact Customer Service →
the error code.
Tableware is not dry.
No rinse aid used or dosage set too low.
1.
Add Rinse aid →
.
2.
Set the amount of rinse aid to be dispensed.
→
"Setting the amount of rinse aid", Page 35
Programme or programme option has no drying
phase, or the drying phase is too brief.
▶
Select a programme with drying, e.g. intensive,
strong or ECO programme.
Some option buttons decrease the drying result, e.g
varioSpeed.
Water collects in recesses of the tableware or cutlery.