background image

– Secure the hood on the wall with the four screws

b

(Fig. 21).

For 

exhaust air mode

proceed as follows:

– Establish the pipe connection. 

– Establish the electrical connection.

– Stainless steel chimney only (LK 010-012/022): 

pull the protective film off the chimney’s trims.

Note:

avoid damaging the sensitive metal surfaces.

– Fit the top chimney duct unit into the base. Make

sure that the fastening holes on the side are at the
top. 

– Put both chimney duct units onto the hood. 

– Pull the top chimney duct unit up into its final

position and secure it with 2 screws on the ceiling
holder (Fig. 22).

Note: 

avoid scratches when pulling the elements

apart by placing the assembly template, for
example, over the edge of the bottom chimney
paneling to protect it. 

– Reinsert the grease filters.

– Place the glass plates on the appliance with the

printed side facing down.

Note:

when putting the glass trays in place, make

sure that you do not scratch the chimney.

16

Fig. 21

Fig. 22

Summary of Contents for AW 540-120

Page 1: ...Operating and Assembly Instructions AW 540 190 120 AW 541 190 120 AW 542 120 AW 543 120 Extractor Hood ...

Page 2: ......

Page 3: ...s Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions Page 12 17 6 1 Technical data Page 12 6 2 Installation Page 12 17 ...

Page 4: ...notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on page 4 that you ought to observe before operating the appliance for the first time The chapters entitled Structure and operating principle and Operation w...

Page 5: ...ance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be switched off at fuse point Repairs must be carried out by authorised spe...

Page 6: ...t there are accessories in the packaging Keep packaging elements e g plastic foil styrofoam parts out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order 1 3 About use The appliance is intended solely for use in the househ...

Page 7: ...64 m LK 011 022 for ceiling heights of 2 64 3 02 m Installation accessories for circulating air mode Stainless steel design ventilation duct LK 010 112 for ceiling heights of 2 36 2 64 m LK 010 122 for ceiling heights of 2 64 3 02 m Aluminium design ventilation duct LK 011 112 for ceiling heights of 2 36 2 64 m LK 011 122 for ceiling heights of 2 64 3 02 m Fig 2 1 2 3 4 Fig 3 Motor off Extraction ...

Page 8: ...ed on or off regardless of whether the wall extractor is in operation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan levels Three fan speeds and one intensive speed are available see Fig 5 You set the fan level required for each respective cooking situation ...

Page 9: ...ress the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like to end the intensive level before the five minutes have elapsed press the 0 key Motor off or select a different level see Fig 8 It is possible to switch off the extraction function at any time by pres...

Page 10: ...ff time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour You can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key s...

Page 11: ...ds out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported vertically to allow food or rinsing residues to drain off If possible the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters Caution when cleaning the inside ...

Page 12: ...a soft cloth and mild detergent solution Do not use any strong caustic or abrasive cleaning agents Do not use any abrasive sponges or brushes either Clean the stainless steel extractor hood AW 540 AW 542 with stainless steel cleaner Cleaning the glass plates Apply commercially available window cleaning agent with a soft moist cloth To facilitate cleaning you can detach the glass plates as follows ...

Page 13: ... tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use Risk of burns Detach the ring from the lamp cover Note make sure that the glass will not fall out Fig 16 Pull out the lamp Fig 17 Defective lamps must only be replaced by lamps of the same type 12 V...

Page 14: ... bottom edge of the wall hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the wall hood is 700 mm for gas appliances The hood can be used in the exhaust or circulating air mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhau...

Page 15: ...e The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct LK 010 012 for ceiling heights of 2 25 2 64 m LK 010 022 for ceiling heights of 2 64 3 02 m Aluminium design ventilation duct LK 011 012 for ceiling heights of 2...

Page 16: ...d can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction function is realised by an external fan module We recommend the fan modules GB 032 107 or GB 052 053 140 from our Gaggenau range the extractor s electronic circuitry is optimised for these fan modul...

Page 17: ...fix the two hooks d with the countersunk screws c Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Hang the hood on the two hook...

Page 18: ...the fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2 screws on the ceiling holder Fig 22 Note avoid scratches when pulling the elements apart by placing the assembly template for example over the edge of the bottom chimney paneling to protect it Reinsert the grease filters Place the g...

Page 19: ...blish the electrical connection Stainless steel chimney only LK 010 112 122 pull the protective film off the chimney s trims Note avoid damaging the sensitive metal surfaces Fit the top chimney duct unit into the base Make sure that the fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2...