background image

 
 

 
 
 
 
 
 

 

 
 
 
 
 

INSTALLATION AND 

USER’S MANUAL

 

Summary of Contents for incanto

Page 1: ...INSTALLATION AND USER S MANUAL ...

Page 2: ... Shock Hazard 3 WALL MOUNTING INSTALLATION 4 Prepare for installation 4 Installation Vent outside 5 Installation Vent inside 8 ISLAND MODEL INSTALLATION 9 SLIM MODEL INSTALLATION 11 OPERATION 14 MAINTENANCE 17 TROBULESHOOTING 19 ENVIRONMENTAL PROTECTION 20 ...

Page 3: ...if cleaning is not carried out in accordance with the instructions No direct baking from the gas cooker Do not flame under the range hood Before connecting this appliance check that the power supply cord is not damaged A damage supply cord must be replaced by qualified service personnel only Ensure adequate ventilation of the room when the range hood is used at the same time as gas appliances The ...

Page 4: ... connected as below picture by means of an extraction duct enamel aluminum flexible pipe or inflammable material with an interior diameter of 150mm b Before installation turn the unit off and unplug it from the outlet c The cooker hood should be placed at a distance of 65 75cm above the cooking plane for best effect ...

Page 5: ...other than electricity are simultaneously in operation the negative pressure in the room must be not exceed 4 Pa 4 10 5 Bar Drill 3 x 8mm holes to accommodate the bracket Screw and tighten the bracket onto the wall with the screws screw plugs provided Lift up the cooker hood and hang onto the wall bracket hook Fix the one way valve to the air outlet of the cooker hood Then attached the exhaust pip...

Page 6: ...ey to adjust the chimney height When the height you require is reached hang the fixing hole to the fixing screws as showed in below pictures Drill 2 8mm holes to accommodate the plate II Screw and tighten the plate II onto the wall with 2 screws provided Assemble the chimney onto the unit and fix it with 2 screws Upper chimney Lower chimney Plate II Rawl plug Screw 4mmx8mm Screw 4mmx30mm ...

Page 7: ...of 4x8mm screws Slide the chimney to adjust the chimney height When the height you require is reached fix 2 pcs of 4x8mm screws onto the hole fixing with plate I as showed in below pictures Drill 2 x 8mm holes to accommodate the plate II Screw and tighten the plate II onto the wall with 2 screws provided Assemble the chimney onto the unit and fix it with 2 screws ...

Page 8: ... to trap odors In order to install the activated carbon filter the grease filter should be detached first Press the lock and pull it downward Plug the activated carbon filter into the unit and turn it in clockwise direction Repeat the same on the other side NOTE o Make sure the filter is securely locked Otherwise it would loosen and cause danger o When activated carbon filter is attached the sucti...

Page 9: ...end the angle bars to the required height and then fix them in position using the 16 x M5 screws and nuts with metal washers IMPORTANT The angle bars must have an overlap of AT LEAST 100 mm 4 If your cooker hood is going to be used in extraction mode then you should connect the ducting hose to the ceiling adaptor at this point Fix the upper chimney section to the hanging plate using the 4 x self t...

Page 10: ...to the ceiling The electrical connection must correspond to the electrical requirement noted on the rating plate which is placed inside the cooker hood The appliance should now be connected to the electrical supply Check that the appliance is operating correctly by selecting each speed and switching the light bulbs on and off Remove the hanging hook and then slide the lower chimney section downwar...

Page 11: ...re distance of hole at the back of the cooker hood Insert the nut into the holes Insert the screws into the nuts and tighten Put the cooker hood onto the tightened screws Fix the cooker hood with safety screw The two safety vents are positioned on the back casing with diameter of 6mm Put the one way valve onto the cooker hood ...

Page 12: ...tection film before installation 3 There are 2 methods for ventilation including horizontal ventilation and vertical ventilation Please pay attention to the ventilation method when installing Vertical ventilation See Pic A please use tool to take out the round cover before using and the air can be vented from top horizontal ventilation See Pic B please use tool to take out the rectangular cover be...

Page 13: ... with carbon filter Turn the adjuster to indoor position install the outlet cover turn on the cooker hood then the air can be vented from the inside outlet Note The charcoal filter is mounted on the back of the grill and must be changed once every three months Warning the charcoal cannot be washed or recycled It should be changed at most after 120 hours using The carbon filter should not be expose...

Page 14: ...s produced press high speed button for highest effective ventilation Light button Electronic button 2 Low Speed button It s used for ventilation in the kitchen Suitable for simmering and cooking which do not give out too much steam Medium Speed button Airflow speed is for ventilation in standard cooking operation High Speed button When high density of smoke or steam produced press high speed butto...

Page 15: ...15 Touch control 1 LCD display 1 Fan symbol will turn when the fan is working 2 Time display 3 Timer 4 Light 5 Fan speed 6 Alarm symbol 7 Cleaning symbol appear when total working time up to 14 hours ...

Page 16: ... stop time can be changed by pressing or Short press for adjusting 1 min and long press for continuous minute change Quick timer When in working mode press and hold and for 1 second Digital display will flash enters into 5 minutes count down After 5 minutes the motor light will turn off automatic there will be a buzzer sound Fan Speed button For changing the speed of the fan during working mode Bo...

Page 17: ...e efficiency of the cooker hood If it is not cleaned the grease residue potentially flammable will saturate on the filter Clean it with household cleaning detergent III Annual Cleaning for Activated Carbon Filter Apply SOLELY to unit that are installed as a recirculation unit not vented to the outside This filter traps odours and must be replaced at least once a year depending on how frequent the ...

Page 18: ...18 Halogen lamp max 20W LED lamp max 1 5W For Slim model ...

Page 19: ...g in to the power supply again Serious Vibration of the unit The fan blade is damaged Switch off the unit and repair by qualified service personnel only The fan motor is not fixed tightly Switch off the unit and repair by qualified service personnel only The unit is not hung properly on the bracket Take down the unit and check whether the bracket is in proper location Suction performance not good ...

Page 20: ...r the environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental r...